> For AI agents: read the machine-readable documentation index at [https://corpuslaw.us/llms.txt](https://corpuslaw.us/llms.txt) or the single-file full reference at [https://corpuslaw.us/llms-full.txt](https://corpuslaw.us/llms-full.txt).

# Or. Rev. Stat. § 701.555 — Barrier-type exterior insulation and finish systems

- **Citation**: Or. Rev. Stat. § 701.555
- **Node Type**: section
- **Jurisdiction**: Oregon (state)
- **Code Body**: Oregon Revised Statutes (2025 edition) (ORS)
- **Official Source**: [https://www.oregonlegislature.gov/bills_laws/ors/ors701.html#701.555](https://www.oregonlegislature.gov/bills_laws/ors/ors701.html#701.555)
- **Canonical URL**: [https://corpuslaw.us/codes/oregon/title-52/chapter-701/section-701-555](https://corpuslaw.us/codes/oregon/title-52/chapter-701/section-701-555)
- **Semantic URL**: [https://corpuslaw.us/codes/oregon/title-52/chapter-701/section-701-555](https://corpuslaw.us/codes/oregon/title-52/chapter-701/section-701-555)

## Hierarchy

Title 52 — Occupations and Professions > Chapter 701 — Construction Contractors and Contracts

## Text

701.555. Barrier-type exterior insulation and finish systems

(1) As used in this section, “barrier-type exterior insulation and finish system” means a foam insulation board inner layer, a polymer and cement base coat middle layer reinforced with glass fiber mesh and a textured finish coat exterior layer, in which:

(a) The layers are bonded to the outside face of an exterior wall;

(b) The middle or exterior layer, but not the inner layer, provides a water resistant barrier for the exterior of the building envelope;

(c) The layers do not provide a means of drainage for water that accumulates behind the exterior surface; and

(d) The layers insulate the building.

(2) A person licensed or required to be licensed under this chapter may not install a barrier-type exterior insulation and finish system on:

(a) A new building; or

(b) An existing building, except as necessary to repair or replace a previously installed barrier-type exterior insulation and finish system.

(3) Subsection (2) of this section does not apply to the application of a barrier-type exterior insulation and finish system:

(a) As an architectural feature that is not intended to protect an interior space of the building; or

(b) To a concrete wall or a concrete masonry unit block wall.

2007 c.851 §2