Floor and wall drainage connections.
Municipal Code of Chicago § 18-29-405.4
in effect18-29-405.4 Floor and wall drainage connections.
Connections between the drain and floor outlet plumbing fixtures shall be made with a floor flange. The flange shall be attached to the drain and anchored to the structure. Connections between the drain and wall-hung water closets shall be made with an approved extension nipple or horn adapter. The water closet shall be bolted to the hanger with corrosion-resistant bolts or screws. Joints shall be sealed with an approved elastomeric gasket or setting compound conforming to FS TT- P-1536a.