For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 91.5.800 — BASIC PROVISIONS

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 91.5.800

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference URL

SEC. 91.5.800. BASIC PROVISIONS.

(Amended by Ord. No. 187,719, Eff. 1/23/23.) Chapter 8 of the CRC is hereby adopted by reference with the following exceptions, modifications and additions. 91.5.802.8. Lateral Support. Roof framing members and ceiling joists having a depth-to-thickness ratio exceeding 2 to 1 based on nominal dimensions shall be provided with lateral support at points of bearing to prevent rotation. For roof rafters with ceiling joists attached per CRC Table R602.3(1), the depth-thickness ratio for the total assembly shall be determined using the combined thickness of the rafter plus the attached ceiling joist. (Readopted by Ord. No. 188,797, Eff. 12/31/25.) 91.5.803.2.4. Openings in Horizontal Diaphragms. Openings in horizontal diaphragms shall conform to LAMC Paragraph 91.5.503.2.4. (Readopted by Ord. No. 188,797, Eff. 12/31/25.)