§ 15.96.070 — Occupant load

Sacramento City Code (current through Supplement No. 4, July 2026, and Ord. 2026-0022) · Sacramento City Code § 15.96.070

Corpus is an independent public-information project, not the official City of Sacramento website. Stable reference URL

15.96.070 Occupant load.

The occupant load for the purpose of establishing exit requirements shall not exceed three hundred (300) square feet per person. If the space is three thousand (3000) square feet or more in area two exits are required. If the space is three thousand (3000) square feet or more it shall be posted for a maximum capacity of forty-nine (49) people. The location of each live/work unit in a multi-unit structure shall be marked by a plaque, diagram or other device visible to emergency personnel from the exterior of the structure containing the units. The location of the plaque, et al, shall be approved by the fire department. (Prior code § 9.29.1306)