For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18-28-1503.1 — Flash point

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-28-1503.1

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference URL

18-28-1503.1 Flash point.

The flash point of any heat transfer liquid used in solar system equipment and appliances shall not be less than the highest temperature as determined from the following: 1. Fifty degrees (28°C) above the design maximum operating (flow) temperature of the fluid in the solar system. 2. Two hundred degrees (111°C) below the design maximum non-operating (no-flow) temperature of the fluid attained in the collector, if the collector manifold assembly is located outside of the building and is exposed to the weather, and the relief valves located adjacent to the collector or collector manifold do not discharge directly into the building. 3. The design maximum no-flow temperature in other collector manifold and relief valve configurations.

§ 18-28-1503.1 — Flash point | Chicago, IL — Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) | Corpus