§ 18-28-801.10.3 — Connection to masonry fireplace flue
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-28-801.10.3
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference URL
18-28-801.10.3 Connection to masonry fireplace flue.
A connector shall extend from the appliance to a flue serving a masonry fireplace such that the flue gases are exhausted directly into the flue. The connector shall be provided with access or shall be removable for inspection and cleaning of both the connector and the flue. Listed direct connection devices shall be installed in accordance with their listing.