§ 18-29-1204.4.10.1 — Water recirculation system outlets
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 18-29-1204.4.10.1
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference URL
18-29-1204.4.10.1 Water recirculation system outlets.
If the pool width does not exceed 20 feet (6096 mm), water recirculation system outlets shall be so located as to provide at least one outlet at the deepest point of the pool. If the pool width is more than 20 feet (6096 mm), multiple outlets shall be provided and spaced not more than 20 feet (6096 mm) apart, nor more than 10 feet (3048 mm) from the walls. All pool drain outlets shall be equipped with gratings having an area of openings not less than 10 times the cross-sectional area of the outlet pipe. The grating shall be designed such that it cannot be readily removed by bathers and will not injure bather’s fingers. (Added Coun. J. 10-14-21, p. 37722, Art. XII, §1)