§ 14X-3-306.2 — Guards
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14X-3-306.2
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference URL
14X-3-306.2 Guards.
Open sides of a stair, landing, balcony, porch, deck, ramp, or other walking surface that is more than 30 inches (762 mm) above the floor or ground immediately below must have guards. Existing guards must be not less than 30 inches (762 mm) in height above the floor of the landing, balcony, porch, deck, ramp, or other walking surface. Existing guards must be not less than 36 inches (914 mm) in height where the walking surface is more than 12 feet (3658 mm) above the floor or ground immediately below. Exceptions: 1. Guards are not required in existing buildings where not required for new construction by the Chicago Building Code. 2. Open sides of a stairway equipped with a handrail on at least one side in accordance with Section 14X-3-306.1, where the walking surface is less than 8 feet (2438 mm) above the floor or ground immediately below.