For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 14X-3-306.2.1 — Opening limitation

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14X-3-306.2.1

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference URL

14X-3-306.2.1 Opening limitation.

Guards that are required to be 36 inches (914 mm) in height by Section 14X-3-306.2 must have balusters or ornamental patterns such that a 6-inch (152 mm) diameter sphere cannot pass through any opening up to a height of 34 inches (864 mm). Exceptions: 1. At elevated walking surfaces provided for access to equipment, openings in guards must not allow passage of a 21-inch (533 mm) diameter sphere. 2. In Group I-3, F, H, and S occupancies, openings in guards must not allow passage of a 21-inch (533 mm) diameter sphere. 3. Approved existing open guards.