§ 10-01 Requirements.
Drums for derrick load and boom hoists shall be contained on the same bedframe operated independently by one or more engines. Each drum shall have a separate hand brake and clutch or power down mechanism in lieu of a clutch, as well as a positive dog on the drum and a dog on the brake pedal. The hoisting mechanism shall be in full view and under the control of a licensed hoisting machine operator at all times.