For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 10-01 — Requirements

New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · 1 RCNY § 10-01

Corpus is an independent public-information project, not the official City of New York website. Stable reference URL

§ 10-01 Requirements.

Drums for derrick load and boom hoists shall be contained on the same bedframe operated independently by one or more engines. Each drum shall have a separate hand brake and clutch or power down mechanism in lieu of a clutch, as well as a positive dog on the drum and a dog on the brake pedal. The hoisting mechanism shall be in full view and under the control of a licensed hoisting machine operator at all times.