PC 1103 — Traps
New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · NYC Plumbing Code § PC 1103
Corpus is an independent public-information project, not the official City of New York website. Stable reference URL
Section PC 1103: Traps
1103.1 Main trap. Leaders and storm drains connected to a combined sewer shall be trapped. Individual storm water traps shall be installed on the storm water drain branch serving each conductor, or a single trap shall be installed in the main storm drain just before its connection with the combined building sewer or the public sewer. A hooded catch basin located within the property line shall be the equivalent of a building-house trap for the connection to a public sewer. 1103.2 Material. Storm water traps shall be of an approved material in accordance with Table 1102.7. 1103.3 Size. Traps for individual conductors shall be the same size as the horizontal drain to which they are connected. 1103.4 Cleanout. An accessible cleanout shall be installed on the building side of the trap.
