MC 309 — Temperature Control
New York City Administrative Code (current through L.L. 2026/147, enacted September 12, 2026, and amendments effective through October 10, 2026) · NYC Mechanical Code § MC 309
Corpus is an independent public-information project, not the official City of New York website. Stable reference URL
Section MC 309: Temperature Control
309.1 Space-heating systems. Interior spaces intended for human occupancy shall be provided with active or passive space-heating systems capable of maintaining an indoor temperature of not less than 68°F (20°C) at a point 3 feet (914.4 mm) above floor on the design heating day. The installation of portable space heaters shall not be used to achieve compliance with this section. Refer to Section 1204 of the New York City Building Code. Exception: Interior spaces where the primary purpose is not associated with human comfort.
