Brazed joints.
Municipal Code of Chicago § 18-28-1203.3.1
in effect18-28-1203.3.1 Brazed joints.
Joint surfaces shall be cleaned. An approved flux shall be applied where required. The joint shall be brazed with a filler metal conforming to AWS A5.8.
Source: City of Chicago, Municipal Code of Chicago (American Legal Publishing, codelibrary.amlegal.com)URL: https://codelibrary.amlegal.com/codes/chicago/latest/chicago_il/0-0-0-2689013Fetched: 10/24/2026