Table 103.4 Requirements for Dead-End Fire Apparatus Access Roads, Amended.
El Paso City Code § 9.52.180.8
in effect9.52.180.8 - Table 103.4 Requirements for Dead-End Fire Apparatus Access Roads, Amended.
Table 103.4 Requirements for Dead-End Fire Apparatus Access Roads, is hereby amended to read as follows:
Length (feet) | Width (feet) | Turnarounds required
0—250 | 20 | None required
251—300 | 20 | 60-foot "T cul-de-sac", 60-foot "Y" or 90-foot-diameter cul-de-sac in accordance with figure D103.1
301—600' See Note 1 | 20 | 90-foot-diameter cul-de-sac in accordance with Figure D103.1
Over 600' See Note 1 | Special approval required | Special approval required
Note 1 - Intermediate turnarounds will be required, spaced at a maximum distance of 600' apart.
(Ord. No. 019521, § 1, 7-5-2023)