Copper or copper-alloy pipe or tubing to galvanized steel pipe.
Municipal Code of Chicago § 18-29-705.18.2
in effect18-29-705.18.2 Copper or copper-alloy pipe or tubing to galvanized steel pipe.
Joints between copper or copper-alloy pipe or tubing and galvanized steel pipe shall be made with a copper-alloy fitting or dielectric fitting. The copper tubing shall be soldered to the fitting in an approved manner, and the fitting shall be screwed to the threaded pipe.
(Amend Coun. J. 10-14-21, p. 37722, Art. VII, § 5)