§ 99.04.106

Los Angeles Municipal Code (2026 Rev. 9, current through legislation effective June 30, 2026) · Los Angeles Municipal Code § 99.04.106

Corpus is an independent public-information project, not the official City of Los Angeles website. Stable reference URL

SEC. 99.04.106.

(Amended by Ord. No. 188,797, Eff. 12/31/25.) 99.04.106.2. Storm Water Drainage and Retention During Construction. Projects which disturb soil shall manage storm water drainage during construction. In order to manage storm water drainage during construction one or more of the following measures shall be implemented to prevent flooding of adjacent property, prevent erosion and retain soil runoff on the site: 1. Retention basins of sufficient size shall be utilized to retain storm water on the site; 2. Where storm water is conveyed to a public drainage system, collection point, gutter, or similar disposal method, water shall be filtered by use of a barrier system, wattle or other method approved by the Department; or 3. Compliance with City of Los Angeles’ storm water management ordinance(s). 99.04.106.5. Cool Roof for Reduction of Heat Island Effect. (Amended by Ord. No. 187,208, Eff. 11/5/21.) Roofing material shall comply with both LAMC Subsections 99.04.106.5.1 and 99.04.106.5.2, or comply with LAMC Subsection 99.04.106.5.3. EXCEPTIONS: 1. Roof repair as defined in Section 100.1(b) of the California Energy Code; or 2. Roof replacement when the roof area being replaced is equal to or less than 50% of the total roof area; or 3. Roof replacement where solar systems are being installed; or 4. Additions resulting in less than 500 square feet of added roof area or less than 50% of the total roof area, whichever is greater; or 5. Roof construction that has a thermal mass over the roof membrane, including areas of vegetated (green) roofs, weighing at least 25 pounds per square foot. 99.04.106.5.1. Solar Reflectance. Roofing material shall have a minimum three-year aged solar reflectance equal to or greater than the values specified in LAMC Tables 99.04.106.5.1 and 99.04.106.5.2. Solar reflectance shall be determined by testing by an approved agency in accordance with ASTM C1549, ASTM E1918 or CRRC-1. Solar reflectance values shall be based on the aged reflectance value of the roofing product or the equation in California Green Building Standards Code (CALGreen) Section A4.106.5.1 if aged solar reflectance values are not available. (Amended by Ord. No. 187,208, Eff. 11/5/21.) 99.04.106.5.2. Thermal Emittance. Roofing materials shall have an emittance value equal to or greater than those specified in LAMC Tables 99.04.106.5.1 and 99.04.106.5.2. Thermal emittance shall be determined by testing by an approved agency in accordance with ASTM C1371, ASTM E408 or CRRC-1. (Amended by Ord. No. 187,208, Eff. 11/5/21.) 99.04.106.5.3. Solar Reflectance Index. Roofing materials shall have a three-year aged Solar Reflectance Index equal to or greater than those specified in LAMC Tables 99.04.106.5.1 and 99.04.106.5.2. Aged Solar Reflectance Index (SRI) may be calculated using the SRI Calculation Worksheet (SRI-WS) developed by the California Energy Commission or in compliance with ASTM E1980-01 as specified in the 2019 California Energy Code. Solar reflectance values used in the SRI-WS shall be based on the aged reflectance value of the roofing product. Certified thermal emittance used in the SRI-WS may be either the initial value or the aged value listed by the Cool Roof Rating Council. (Amended by Ord. No. 187,208, Eff. 11/5/21.) TABLE TABLE 99.04.106.5.1 [LOW-RISE] (Added by Ord. No. 187,208, Eff. 11/5/21.) ROOF SLOPE | MINIMUM 3-YEAR AGED SOLAR REFLECTANCE | THERMAL EMITTANCE | 3 YEAR AGED SOLAR REFLECTANCE INDEX (SRI) ≤ 2:12 | 0.65 | 0.85 | 78 > 2:12 | 0.25 | 0.85 | 20 TABLE 99.04.106.5.2 [HIGH-RISE] (Added by Ord. No. 187,208, Eff. 11/5/21.) ROOF SLOPE | MINIMUM 3-YEAR AGED SOLAR REFLECTANCE | THERMAL EMITTANCE | 3 YEAR AGED SOLAR REFLECTANCE INDEX (SRI) ≤ 2:12 | 0.65 | 0.75 | 78 > 2:12 | 0.25 | 0.75 | 20 99.04.106.7. Reduction of Heat Island Effect for Nonroof Areas [N]. Reduce nonroof heat islands for 50% of pathways patios, driveways or other paved areas by using one or more of the methods listed. 1. Use trees or other plantings to provide shade and that mature within 15 years of planting. Trees shall be suitable in mature size and environmental requirements for the site. Tree selection and placement shall consider location and size of areas to be shaded, location of utilities, views from the structure, distance to sidewalks and foundations, overhangs onto adjacent properties and streets; other infrastructure and adjacent to landscaping. In addition, shading shall not cast a shadow, as specified, on any neighboring solar collectors pursuant to California Public Resources Code Section 25981, et seq. (Solar Shade Control Act); 2. Use high albedo materials with an initial solar reflectance value of at least .30 as determined in accordance with American Society for Testing and Materials (ASTM) Standards E1918 or C1549; 3. Use open grid pavement system or pervious or permeable pavement system; 4. Use solar panel arrays to create a canopy shade system; or 5. Other methods of reducing heat island effects acceptable to the Department. 99.04.106.8. All-Electric Buildings. (Added by Ord. No. 187,714, Eff. 1/23/23.) All newly constructed buildings shall be all-electric buildings. EXCEPTIONS: 1. Application for a building permit is submitted, accepted by the Department of Building and Safety, and building permit application fees are paid prior to April 1, 2023. 2. Application for a building permit for an Affordable Housing Project, as defined in the Mayor's Executive Directive 1.3, is submitted, accepted by the Department of Building and Safety, and building permit application fees are paid prior to June 1, 2023. 3. Attached accessory dwelling units using existing gas piping systems in conjunction with the primary dwelling. 4. Cooking equipment contained within kitchens located in a public use area, as defined in the California Building Code Chapter 2, such as restaurants, commissaries, cafeterias, and community kitchens provided the electrical infrastructure is installed in accordance with Section 99.04.106.8.1. 5. Gas-powered emergency life-safety systems, including emergency backup. 99.04.106.8.1. Requirements for Combustion Equipment. (Added by Ord. No. 187,714, Eff. 1/23/23.) Where required by Section 99.04.106.8, the electrical infrastructure shall be installed to accommodate the future installation of an electrical heating or cooking appliance/equipment in the following ways: 1. Branch circuit wiring, electrically isolated and designed to serve all electrical heating and cooking appliances in accordance with manufacturer requirements and the California Electrical Code, including the appropriate voltage, phase, minimum amperage, and an electrical receptacle or junction box within 5 feet of the appliance that is accessible with no obstructions. Appropriately sized conduit may be installed in lieu of conductors; and 2. Labeling of both ends of the unused conductors or conduit shall be with "For Future Electrical Appliance/Equipment"; and 3. Reserved circuit breakers in the electrical panel for each branch circuit, appropriately labeled (e.g., "Reserved for Future Electric Range/Equipment"), and positioned on the opposite end of the panel supply conductor connection; and 4. Connected subpanels, panelboards, switchboards, busbars, and transformers shall be sized to serve the future electrical heating appliances and equipment. The electrical capacity requirements shall be adjusted for demand factors in accordance with the California Electric Code.