§ 470.310 — Header pipe
Jacksonville Ordinance Code (Supp. No. 6, Update 2: codified through Ordinance No. 2026-492-E, enacted July 28, 2026) · Jacksonville Ordinance Code § 470.310
Corpus is an independent public-information project, not the official City of Jacksonville website. Stable reference URL
Sec. 470.310. - Header pipe.
In lieu of a distribution box, a header pipe may be used if installed in compliance with this Section. A header pipe shall be sewer pipe of vitrified clay at least four inches in diameter with watertight joints. Header pipe is not required to be encased in filter material. The header pipe shall be laid level with direct connections to each drainfield line and septic tank, using appropriate sewer pipe fittings.
(Ord. 70-650-526; Ord. 71-397-181; Ord. 83-591-400, § 1)