§ 27-940 Siamese connections required.

Siamese connections shall be provided as follows: (a) One siamese connection shall be provided for each three hundred feet of exterior building wall or fraction thereof facing upon each street or public space. (b) Where buildings face upon two parallel streets or public spaces without an intersecting street or public space, one siamese shall be provided for each three hundred feet of exterior building wall or fraction thereof facing upon each such parallel street or public space. (c) Where a building faces upon two intersecting streets or public spaces and the total length of the exterior building walls facing upon such streets or public spaces does not exceed three hundred feet only one siamese connection need be installed provided the siamese connection is located within fifteen feet of the corner and on the longer street. (d) Where a building faces on three streets or public spaces, one siamese connection shall be provided for each three hundred feet of building wall or fraction thereof facing upon such streets or public spaces, provided that at least one siamese connection is installed on each of the parallel streets or public spaces, and further provided that the siamese connections shall be located so that the distance between them does not exceed three hundred feet. (e) Where a building faces upon four streets or public spaces, at least one siamese connection shall be provided on each street front or public space; however, only one siamese connection need be provided at the corner of two intersecting streets or public spaces if the siamese connection is located within fifteen feet of the corner and on the longer street or public space, and if the distances between siamese connections, in all cases, does not exceed three hundred feet. (f) In any case where the exterior building walls of a building facing a street or public space is obstructed in part by another building, one siamese connection shall be provided for each clear three hundred feet of exterior building wall or fraction thereof facing upon such street or public space.