Plumbing and related facilities.
San Antonio City Code § 13-99
in effectSec. 13-99. - Plumbing and related facilities.
(a) The plumbing system in each rendering business shall be installed in compliance with this Code.
(b) All outlets and connections to fixtures and equipment shall be so installed as to prevent backflow into the water-distribution system.
(c) Plant sewer lines shall be separate from toilet sewer lines to a point outside the building.
(d) Where necessary to prevent discharge into the sewage collection system of solid wastes likely to clog the system, the liquid wastes containing such solid materials shall be passed through a separator or indirect waste receptor which shall effectively retain such solids prior to discharge into the sewage collection system.
(e) All overhead drain lines and piping shall be so located and installed or so protected that leakage and condensation therefrom will not drip upon employees, processing equipment, utensils, finished product, or floors in working areas.
(f) Drinking water facilities of a sanitary type shall be provided and maintained in good working order in the establishment and shall be so located as to be convenient for use by employees.
(Ord. No. 2008-05-15-0402, § 1(Att. I), 5-15-08)
Source: City of San Antonio, City Code, City Charter and Unified Development Code (Municode Library, library.municode.com)URL: https://library.municode.com/tx/san_antonio/codes/code_of_ordinances?nodeId=PTIICO_CH13FOFOHA_ARTVRE_S13-99PLREFAFetched: 10/27/2026