§ 31-120. - Bathroom facilities required.
The following sanitary facilities are required:
(1) toilets for males: four toilets; in addition, for every 25 non-served spaces, an additional toilet shall be provided. Urinals may be acceptable for ⅓ of the toilets required. An equal number of lavatories shall be provided for all toilets and urinals.
(2) toilets for females: four toilets; in addition, for every 25 non-served spaces, an additional toilet shall be provided. An equal number of lavatories shall be provided for all toilets.
(3) showers for both sexes: Each sex shall be provided with at least two showers with individual dressing accommodations. In addition, there shall be one additional shower for each sex for every ten non-served RV spaces or fraction thereof.
(4) each toilet for females and each shower with individual dressing accommodations for females shall be in a private compartment or stall.
(5) the toilet and other sanitation facilities for males and females shall either be in a separate building or shall be separated, if in the same building, by a soundproof wall.
(Code 1980, § 31-120; Ord. No. 18826, § 1, 8-25-87)