§ 17.101G.050 — Property development standards
Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Planning Code § 17.101G.050
Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/5bc3fc7d-5c03-462f-9845-596898f871bc
17.101G.050 - Property development standards.
A. Zone Specific Standards. Table 17.58.03 below prescribes development standards specific to individual zones. The number designations in the right-hand column refer to the additional regulations listed at the end of the Table. "N/A" designates the standard is not applicable to the specified zone. Table 17.101G.03: Property Development Standards Development Standards | Zones | Additional Regulations D-LM-1 | D-LM-2 | D-LM-3 | D-LM-4 | D-LM-5 Minimum Lot Dimensions Width | 25 ft. | 25 ft. | 50 ft. | 50 ft. | 50 ft. | 1 Frontage | 25 ft. | 25 ft. | 50 ft. | 50 ft. | 50 ft. | 1 Lot area | 3,000 sf. | 3,000 sf. | 7,500 sf. | 7,500 sf. | 7,500 sf. | 1 Minimum/Maximum Setbacks Minimum front | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 2, 9 Maximum front and street side for the first story | N/A | 5 ft. | 5 ft. | 10 ft. | N/A | 3, 9 Maximum front and street side for the second and third stories or thirty-five (35) feet, whatever is lower | N/A | 5 ft. | 5 ft. | N/A | N/A | 3, 9 Minimum interior side | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 2 Minimum corner side | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 2 Rear | 10 ft. | 0 ft. | 0 ft. | 0 ft. | 0 ft. | 2 Average minimum setback from the Lake Merritt Estuary Channel | 60 ft. | 60 ft. | 60 ft. | 60 ft. | 60 ft. | 4, 9 Design Regulations Minimum facade transparency of ground floor Nonresidential Facilities | 55% | 65% | 55% | 55% | 55% | 5, 10 Minimum height of ground floor Nonresidential Facilities | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 6 Minimum width of storefronts | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 15 ft. | 7 Minimum separation between grade and ground floor living space | 2.5 ft. | N/A | N/A | 2.5 ft. | N/A | 8 Additional Regulations for Table 17.101G.03: 1. See Sections 17.106.010 and 17.106.020 for exceptions to lot area, width and street frontage regulations. 2. See Section 17.108.040 for the minimum front yard setback when fifty percent (50%) or more of the frontage on the same block and side of the street is in a Residential Zone. 3. The following notes apply to the maximum yard requirements: a. The requirements only apply to the construction of new principal buildings and to no more than two property lines. One of these property lines shall abut the principal street. b. The requirements do not apply to lots containing Recreational Assembly, Community Education, Utility and Vehicular, or Extensive Impact Civic Activities or Automobile and Other Light Vehicle Gas Station and Servicing Commercial Activities as principal activities. c. These maximum yards apply to seventy-five percent (75%) of the street frontage on the principal street and fifty percent (50%) on other streets, if any. All percentages, however, may be reduced to fifty percent (50%) upon the granting of Regular Design Review (see Chapter 17.136 for the design review procedure). In addition to the criteria contained in 17.136.050, the proposal must also meet each of the following criteria: i. Any additional yard area abutting the principal street is designed to accommodate publicly accessible plazas, sidewalk cafes, or restaurants; ii. The proposal will not impair a generally continuous wall of building facades; iii. The proposal will not weaken the concentration and continuity of retail facilities at ground-level, and will not impair the retention or creation of an important shopping frontage; and iv. The proposal will not interfere with the movement of people along an important pedestrian street. d. The maximum yard requirements above the ground floor may be waived upon the granting of a conditional use permit (see Chapter 17.134 for the CUP procedure). In addition to the criteria contained in Section 17.134.050, the proposal must also meet each of the following criteria: i. It infeasible to both accommodate the use proposed for the space and meet the maximum yard requirement; ii. The proposal will not weaken the street definition provided by buildings with reduced setbacks; and iii. The proposal will not interrupt a continuity of 2nd and 3rd story facades on the street that have minimal front yard setbacks. 4. This regulation is the average setback distance, measured from the mean high tide line, along the total length of channel frontage involved in a project, with a minimum setback at any point of forty (40) feet. 5. This percentage of transparency is only required for principal buildings that include ground floor Nonresidential Facilities, and only applies to the facade facing the principal street. On all other street facing facades, the requirement is one-half (½) the standard for the facade facing the principal street. The area of required transparency is between two (2) feet and nine (9) feet in height of the ground floor and must be comprised of clear, non-reflective windows that allow views out of indoor activity space or lobbies. Glass block does not qualify as a transparent window. Exceptions to this regulation may be allowed by the Planning Director for unique facilities such as convention centers, gymnasiums, parks, gas stations, theaters and other similar facilities. 6. This height is required for new principal buildings that include ground floor Nonresidential Facilities, and is measured from the sidewalk grade to the second story floor. 7. This regulation only applies to new construction of ground floor storefronts as part of a mixed use development project. Also see Lake Merritt Station Area Plan Design Guidelines for further guidance. 8. This regulation only applies to ground floor living space located within fifteen (15) feet of a street frontage. 9. Vehicular Residential Facilities shall be located a minimum of thirty (30) feet from the street or be located behind a building. See Section 17.103.085 for additional setback and separation requirements for Vehicular Residential Facilities. 10. For ground floor Health Care Civic Activities, Medical Service Commercial Activities, and Animal Care Commercial Activities, this level of transparency shall apply to the street-fronting adjacent spaces, such as reception, lobby, and waiting areas. Medical treatment rooms shall not face the street. B. Height, Bulk, and Intensity Area Specific Standards. Table 17.101G.04 below prescribes height, bulk, and intensity standards associated with the height/bulk/intensity areas described in the Zoning Maps. The numbers in the right-hand column refer to the additional regulations listed at the end of the Table. "N/A" designates the regulation is not applicable to the specified Height/Bulk/Intensity Area. Table 17.101G.04 Height, Density, Bulk, and Tower Regulations Regulation | Height/Bulk/Intensity Areas | Notes LM-45 | LM-95 | LM-175 | LM-275 Maximum Height Building Base | N/A | N/A | 45 ft. base; 95 ft. base upon granting of CUP and additional findings in Note 2.a, b, c | 45 ft. base; 95 ft. base upon granting of CUP and additional findings in Note 2.a, b, c | 1 Maximum Height Total | 45 ft. | 95 ft. | 175 ft. | 275 ft. | 2 Height Area Exceptions Allowed With Conditional Use Permit (CUP) | N/A | LM-175 standards allowed for 5 bldgs. total (2 on east side and 3 on west side of Lake Merritt Channel); LM-275 standards allowed for 3 bldgs. total (1 on east side and 2 on west side of Lake Merritt Channel) | LM-275 standards allowed for 3 bldgs. total | Not applicable | 2 (see additional CUP findings in Note 2 below) Minimum Height New principal buildings | 25 ft. | 35 ft. | 35 ft. | 35 ft. | 3 Maximum Residential Density (Square Feet of Lot Area Required Per Unit) Regular Dwelling Unit | 450 | 225 | 110 | 110 | 2, 4 Rooming Unit | 225 | 110 | 55 | 55 | 2, 4 Efficiency Dwelling Unit | 225 | 110 | 55 | 55 | 2, 4 Maximum Nonresidential Intensity (Floor Area Ratio) Maximum Nonresidential Floor Area Ratio (FAR) | 2.5 | 5 7.2 if on BART-owned parcel subject to AB2923 (2018) | 8 | 12 | 2, 4 Tower Regulations Setback of Tower from Building Base for Residential Buildings | N/A | N/A | 10 ft., along at least 50% of the perimeter length of the building base | 10 ft., along at least 50% of the perimeter length of the building base | 2, 6, 7 Maximum Average per Story Lot Coverage for Residential Buildings | N/A | N/A | 70% of site area or 15,000 sf, whichever is greater | 75% of site area or 15,000 sf, whichever is greater | 2, 5, 6 Maximum Average per Story Lot Coverage for Nonresidential Buildings | N/A | N/A | 80% of site area or 30,000 sf, whichever is greater | 80% of site area or 30,000 sf, whichever is greater | 2, 5, 6 Maximum Tower Elevation Length for Residential Buildings | N/A | N/A | 150 ft. | 150 ft. | 2, 5, 6 Maximum Diagonal Length for Residential Buildings | N/A | N/A | 180 ft. | 200 ft. | 2, 5, 6 Minimum Distance Between Towers on the Same Lot for Residential Buildings | N/A | N/A | 40 ft. | 40 ft. | 2, 6 Notes: 1. See Section 17.108.030 for allowed projections above height limits and Section 17.108.020 for increased height limits in certain situations. 2. Height Area Exceptions. In Height/Bulk/Intensity Areas LM-95 and LM-175, a limited number of buildings, as prescribed above in Table 17.101G.04, may be allowed to utilize the same height/bulk/intensity standards that typically apply to either Height/Bulk/Intensity Area LM-175 or LM-275 upon determination that the proposal conforms to the general use permit criteria set forth in the conditional use permit procedure in Chapter 17.134 and to the following additional use permit criteria: a. The proposal is consistent with the intent and desired land use character identified in the Lake Merritt Station Area Plan and its associated policies; b. The proposal will promote implementation of the Lake Merritt Station Area Plan; and c. The proposal is consistent with the desired visual character described in the Lake Merritt Station Area Plan and Lake Merritt Station Area Design Guidelines, with consideration given to the existing character of the site and surrounding area. The following application process for a height area exception shall be followed: i. Applications for any of the limited number of allowed height area exceptions prescribed in Table 17.101G.04 shall be reviewed on a first come, first served basis. ii. A project shall secure a position as one of the specified height area exceptions following final Conditional Use Permit approval. Such Conditional Use Permits shall include a condition of approval that establishes a schedule for: submittal of a building permit application, timely response to plan check comments, payment of building permit fees such that a building permit can be issued, and commencement of construction. The process for allowing extension of the timeline requirements, if any, shall be specified in the condition. iii. Failure of a permittee to strictly comply with the schedule established by the Conditional Use Permit shall be grounds for revocation of the Conditional Use Permit pursuant to Chapter 17.134. Notwithstanding the provisions above, BART owned properties subject to Assembly Bill (AB) 2923 (2018) shall be permitted a building height of up to twelve (12) stories for all activities. 3. This minimum height excludes the height of the allowed projections into the height limit contained in Section 17.108.030. 4. For mixed use projects in the D-LM Zones, the allowable intensity of development shall be measured according to both the maximum nonresidential Floor Area Ratio (FAR) allowed by the zone and the maximum residential density allowed by the zone. The total lot area shall be used as a basis for computing both the maximum nonresidential FAR and the maximum residential density. 5. The maximum tower elevation length, diagonal length, and average per story lot coverage above the building base may be increased by up to thirty percent (30%) upon determination that the proposal conforms to the general use permit criteria set forth in the conditional use permit procedure in Chapter 17.134 and to the following additional use permit criteria: a. The proposal will result in a signature building within the neighborhood, City, or region based on qualities, including but not limited to, exterior visual quality, craftsmanship, detailing, and high quality and durable materials. 6. For the purpose of this regulation, a "nonresidential building" means a building with more than one-third (⅓) floor area devoted to Nonresidential Activities, and a "residential building" means a building with at least two-thirds (⅔) floor area designated for Residential Activities. 7. The following additional regulations apply to the tower stepback: a. Unenclosed recreational, landscaping, and open space facilities are permitted within this stepback area. b. A lesser stepback is permitted if it precludes the construction of the maximum average per story lot coverage. c. For nonresidential towers, a stepback is only required on sites adjacent to a right-of-way that is less than eighty (80) feet.
(Ord. No. 13868, § 2(Exh. A), 12-16-2026; Ord. No. 13763, § 5, 10-3-2023; Ord. No. 13677, § 4(Exh. A), 1-18-2022; Ord. No. 13666, § 3(Exh. A), 11-16-2021; Ord. No. 13357, § 3(Exh. A), 2-16-2016; Ord. No. 13302, § 5(Exh. C), 4-21-2015; Ord. No. 13276, § 5(Exh. A), 12-9-2014)
Ask a question about Oakland law
Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
