§ 17.101K.100 — Base Height and Intensity Standards
Oakland Municipal Code (Supp. No. 103: codified through Ordinance No. 13873, adopted February 17, 2026) · Oakland Planning Code § 17.101K.100
Corpus is an independent public-information project, not the official City of Oakland website. Stable reference: corpuslaw.us/code/1b85e085-7d7b-4d86-a4e3-4be8450a6d9e
17.101K.100 - Base Height and Intensity Standards.
Base Height and Intensity Standards. Table 17.101K.05 below prescribes height and intensity standards in the DDT Zones for projects not participating in the Zoning Incentive Program (ZIP), which is described in Section 17.101K.110. The numbers in the right-hand column refer to the additional regulations listed at the end of the Table. "N/A" designates the regulation is not applicable to the specified Height and Intensity Area. The base height and intensity standards may be exceeded through the ZIP and/or through State Density Bonus Law (CA Gov't Code Section 65915 et seq.). Refer to Section 17.101K.110 for the D-DT Zoning ZIP Height and Intensity Regulations, which specify the maximum amount of development if a project participates in the ZIP. Refer to Section 17.107.040 for the City's Density Bonus regulations. Table 17.101K.05 Base Height and Intensity Regulations, Height and Intensity Areas 1—11 Regulation | Base Height and Intensity Area (HIA) | Notes 1 | 2 | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 Maximum Density (Square Feet of Lot Area Required Per Unit) Regular Dwelling units | 1,000 | 900 | 450 | 300 | 1,000 | 450 | 260 | 250 | 225 | 110 | 1, 2 Rooming Units | 500 | 450 | 225 | 150 | 500 | 225 | 130 | 125 | 110 | 55 | 1, 2 Efficiency Dwelling Units | 500 | 450 | 225 | 150 | 500 | 225 | 130 | 125 | 110 | 55 | 1, 2 Maximum Nonresidential Floor Area Ratio | 1.0 | 2.0 | 2.5 | 2.0 | 3.5 | 5.0 | 7.0 | 5.0 | 5.0 | 7.5 | 2 Maximum Height | 45 ft. | 45 ft. | 45 ft. | 45 ft. | 55 ft. | 65 ft. | 65 ft. | 65 ft. | 95 ft. | 95 ft. | 3, 4 Minimum Height | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | 45 ft. | 45 ft. Building Base Regulations Minimum Base Height | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Maximum Base Height | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Maximum front and street side setback for each story | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Tower Regulations Average per story lot coverage for nonresidential buildings | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Average per story lot coverage for residential buildings | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Maximum elevation length for residential towers | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Maximum diagonal length for residential towers | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Minimum distance between towers on the same lot for residential towers | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Minimum front and street side stepback from the façade of the base | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A | N/A Table 17.101K.05 (continued), Height and Intensity Areas 13-25 Regulation | Base Height and Intensity Area | Notes 11 | 12 | 13 | 14 | 15 | 16 | 17 | 18 Maximum Density (Square Feet of Lot Area Required Per Unit) Regular Dwelling units | N/A | 250 | 110 | 110 | 100 | 90 | 90 | 90 | 1, 2 Rooming Units | N/A | 125 | 55 | 55 | 50 | 45 | 45 | 45 | 1, 2 Efficiency Dwelling Units | N/A | 125 | 55 | 55 | 50 | 45 | 45 | 45 | 1, 2 Maximum Nonresidential Floor Area Ratio | 7.5 | 5.0 | 8.0 | 12.0 | 14.0 | 17.0 | 20.0 | 20.0 | 2 Maximum Height | 95 ft. | 135 ft. | 175 ft. | 175 ft. | 275 ft. | 275 ft. | 450 ft. | No Limit | 3, 4 Minimum Height | N/A | 110 ft. | 65 ft. | 65 ft. | 65 ft. | 65 ft. | 110 ft. | 110 ft. | 4, 5, 6, 7 Building Base Regulations Minimum Base Height | N/A | 45 ft. | 45 ft. | 45 ft. | 55 ft. | 55 ft. | 65 ft. | 65 ft. | 7, 8 Maximum Base Height | N/A | 65 ft. | 95 ft. | 95 ft. | 95 ft. | 95 ft. | 95 ft. | 95 ft. Maximum front and street side setback for each story | N/A | Same as maximum ground floor front and street side setbacks in Table 17.101K.04 | 9 Tower Regulations Average per story lot coverage for nonresidential buildings | N/A | 80% of site area or 30,000 sf., whichever is greater | 80% of site area or 30,000 sf., whichever is greater | 80% of site area or 30,000 sf., whichever is greater | 80% of site area or 30,000 sf., whichever is greater | 80% of site area or 30,000 sf., whichever is greater | 80% of site area or 30,000 sf., whichever is greater | 85% of site area or 40,000 sf., whichever is greater | 10, 11, 12, 13 Average per story lot coverage for residential buildings | N/A | 70% of site area or 15,000 sf., whichever is greater | 70% of site area or 15,000 sf., whichever is greater | 70% of site area or 15,000 sf., whichever is greater | 75% of site area or 15,000 sf., whichever is greater | 75% of site area or 15,000 sf., whichever is greater | 75% of site area or 20,000 sf., whichever is greater | 85% of site area or 25,000 sf., whichever is greater | 10, 11, 12, 13 Maximum elevation length for residential towers | N/A | 150 ft. | 150 ft. | 150 ft. | 150 ft. | 150 ft. | 175 ft. | 200 ft. Maximum diagonal length for residential towers | N/A | 180 ft. | 180 ft. | 180 ft. | 200 ft. | 200 ft. | 210 ft. | 235 ft. Minimum distance between towers on the same lot for residential towers | N/A | 40 ft. | 40 ft. | 40 ft. | 40 ft. | 40 ft. | 40 ft. | 40 ft. Minimum stepback from base on two facades for residential towers | N/A | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10 ft. | 10, 12, 14, 15 Notes: 1. See Chapter 17.107 for affordable and senior housing density incentives and Section 17.101K.120 for the transfer of development rights from other parcels in the Downtown District (D-DT) Zones. 2. For mixed use projects in the D-DT Zones, the allowable intensity of development shall be measured according to both the maximum nonresidential Floor Area Ratio (FAR) allowed by the zone and the maximum residential density allowed by the zone. The total lot area shall be used as a basis for computing both the maximum nonresidential FAR and the maximum residential density. 3. See Section 17.108.030 for allowed projections above height limits and Section 17.108.020 for increased height limits for civic buildings. 4. In the D-DT-CPW Zone, no new additions, accessory structures, or principal buildings shall be constructed unless they are either: 1) part of a project that includes the construction of a principal building that is at least one hundred (100) feet in height, or 2) on a site that contains an existing principal building that is at least one hundred (100) feet in height to the floor of the top story. This minimum height excludes the height of the allowed projections into the height limit contained in Section 17.108.030, Sign Facilities, and Telecommunications Facilities. Also, see Section 17.101K.040, which requires the granting of a Planned Unit Development Permit for all new construction and additions. 5. This minimum height excludes the height of the allowed projections into the height limit contained in Section 17.108.030, Sign Facilities, and Telecommunications Facilities. 6. The minimum height limit of properties within the Employment Priority Combining Zone is one hundred seventy-five (175) feet. 7. Buildings constructed to accommodate Essential Service, Utility and Vehicular, or Extensive Impact Civic Activities as principal activities are exempted from the height minimum regulation. The allowed projections into the height limits contained in Section 17.108.030 are not counted towards the height minimum. 8. The minimum height of the base can be reduced to allow transition to a lower-scale neighboring Potentially Designated Historic Property (PDHP) or Designated Historic Property. 9. These required setbacks are in Table 17.101K.04 and include Note 3 of that table. Also, see Section 17.108.030 for allowed projections above height limits. 10. Sections 17.101K.130(A)(1)(b) and 17.101K.130(A)(1)(c) for more tower and base requirements. 11. The average floor plate area of the stories above the base cannot exceed this percentage of lot area, with the following two qualifications: a. The floor plate area of an individual story cannot be more than fifteen percent (15%) greater than the maximum average per story floor area above base. b. A story that is more than fifteen percent (15%) less than the maximum average floor plate area is not included in the average per story floor area above the base. 12. This regulation does not apply in the Employment Priority Combining Zone. 13. For the purpose of this regulation, a "nonresidential building" means a building with more than one-third (⅓) floor area devoted to Nonresidential Activities. 14. For the purpose of this regulation, a "residential building" means a building with at least two-thirds (⅔) floor area designated for Residential Activities. 15. The following additional regulations apply to the tower stepback: a. Unenclosed recreational, landscaping, and open space facilities are permitted within this stepback area. b. A lesser stepback is permitted if it precludes the construction of the maximum average per story lot coverage. c. For nonresidential towers, a stepback is only required on sites adjacent to a right-of-way that is less than eighty (80) feet.
(Ord. 13812, § 4(Exh. A), 7-30-2024)
Ask a question about Oakland law
Corpus searches the Oakland sections it holds and shows the ones that match, with their citations. Free, no sign-in.
