For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 47-37B.6 — Uptown Urban Village Zoning District special regulations

Code of Ordinances, City of Fort Lauderdale, Florida (Supp. No. 67: codified through Ordinance No. C-26-32, enacted July 2, 2026) · Fort Lauderdale Unified Land Development Regulations § 47-37B.6

Corpus is an independent public-information project, not the official City of Fort Lauderdale website. Stable reference: corpuslaw.us/code/3f227447-a09b-47ec-a1b3-106dd3a571b2

Sec. 47-37B.6. - Uptown Urban Village Zoning District special regulations.

A. Applicability. The following special regulations shall apply to all development permitted within the Uptown Urban Village zoning districts and shall be used in conjunction with the Uptown Urban Village Illustrations of Design Standards. B. Open space requirements. 1. Pocket parks shall be provided for all residential development and mixed-use development containing residential uses. Common areas such as private amenity decks or pool decks can be counted toward the pocket park requirements at no greater than forty (40) percent of such private amenity square foot area. 2. Communal space shall be provided based on residential unit size and the percentage of such in a development. Communal space may be at grade or within a building but cannot include amenity areas such as pool decks or fitness facilities. 3. Plaza/gathering areas shall be provided for commercial uses or mixed-use development containing commercial uses and is based on the total square footage of commercial use. Outdoor dining can be credited toward plaza/gathering area requirements. 4. Pocket parks and plaza/gathering areas that are connected, abutting, or immediately adjacent to one another can be reduced by fifty (50) percent of required area. 5. Spatial requirements for Section 47-37B.6.B.1 through Section 47-37B.6.B.3 are provided in Table 47-37B.6.C, Spatial Requirements for Open Space. 6. Landscape requirements not specified herein shall comply with Section 47-21. C. Table of Spatial Requirements for Open Space. Requirements Pocket Park (sq. ft.) | Communal Space (sq. ft.) | Plaza/Gathering Area (sq. ft.) Residential and Mixed Use Development containing Residential 50 units or less | 200 per unit | - | - 51 units to 150 units (Note A) | 150 per unit 10,000 sq. ft. (min.) | - | - 151 units or more (Note A) | 100 per unit 22,500 sq. ft. (min.) | - | - Development with 50% or less of the units at 400 (sq. ft.) | - | 1,500 (min) | - Development with 51% or more of the units at 400 (sq. ft.) | - | 3,000 (min) | - Commercial and Mixed Use Development containing Commercial 10,000 to 30,000 (sq. ft.) of commercial use | - | - | 1,000 to 3,000 30,000 (sq. ft.) or greater of commercial use | - | - | 3,000 to 5,000 Note A: The minimum square foot space provided shall not be less than the maximum square foot space for the unit category that precedes it, which has been noted as the minimum. D. Street hierarchy. Development applications shall construct or improve the streets listed below by demonstrating compliance with the street cross sections as identified in the Uptown Master Plan. In the event the street is under jurisdiction of another local government or Broward County, then such deviations to the street cross section required by that jurisdiction shall not be considered an alternate design solution to the Uptown regulations. 1. Primary streets include Cypress Creek Road, N Andrews Avenue, and N Powerline Road. Primary streets are major arterials designed to move regional traffic through the Uptown Urban Village. This street typology is proposed to largely remain as is, though some changes to configuration will occur with the implementation of I-95 interchange modifications, particularly at Cypress Creek Road. 2. Secondary streets include NW 65 th Court, NW 63 rd Street, NW 5 th Way, NW 59 th Court, and NW 6 th Way. Secondary streets provide internal connectivity within sub-areas of the Uptown Urban Village. This street typology is proposed to be modified to accommodate a variety of multi-modal improvements depending on the location within the area. 3. Tertiary streets include NW 67 th Street, NW 2 nd Avenue, NW 57 th Place, NW 57 th Court, and NW 57 th Street and newly-proposed roads in Sub-Area Planning Districts 1, 2, 3 and 5 within the Uptown Urban Village. Tertiary streets are internal connectors identified primarily for service and site access to individual development sites. E. Drive-thru design. Drive-thru facilities shall not directly face primary and secondary streets and shall incorporate the following site design requirements. 1. Drive-thru facilities shall not be free-standing building and shall be integrated into a building that contains a minimum of two (2) other uses. 2. Access to the drive-thru facilities may be through a single curb cut on Secondary Street or from an internal circulation drive. 3. Drive-thru windows and point of purchase signage such as menu boards shall not front a public street and shall be located on the side or rear of the building. 4. Landscaping shall screen the drive-thru aisle from adjacent users to minimize the visual impact. F. Building design. Building facades facing primary and secondary streets shall include building articulation that meets the following design elements: 1. For every one hundred (100) feet of building facade length, there shall be a minimum of three (3) feet of building articulation including but not limited to projections, recesses, or reveals; 2. First two (2) floors shall contain a minimum of two (2) building materials of high quality. Stucco shall not be counted to meet the two (2) material requirement; and 3. Building corners shall contain special corner treatments both vertically and horizontally with varying angles to emphasize the building corner. Entrances located in building corners shall contain enhanced architectural elements such as large awnings or canopies, significant banding treatments, or other unique design material. G. Arrangement of uses. Mixed-use developments are required to arrange uses based on the following: 1. Mixed-use development arranged in a horizontal configuration shall be designed with the residential use facing other residential use, or open space, or the principal front entrance of non-residential or mixed-use buildings located across a public street so that the front of the residential use does not face surface parking lots, parking structures, or back of non-residential buildings. 2. Mixed-use development arranged in a vertical configuration must contain non-residential uses as part of the ground floor with the exception of principal entrance for the residential use or the incorporation of live-work unit. H. Parking, passenger loading and bicycle storage. 1. Off-street parking in the UUV-NE district shall be located behind the front setback of the building nearest to Andrews Avenue with the exception that no more than one (1) aisle of parking fronting Andrews Avenue. 2. Off-street parking in the UUV-NW and UUV-SE districts shall be located behind the front setback of the building nearest to primary and secondary streets. 3. Off-street parking shall be organized into parking lot areas with no more than two hundred (200) spaces separated by any of the following elements; buildings, open space, enhanced landscaped areas, water bodies, or plaza/gathering areas. 4. Off-street parking requirements including parking reductions and exemptions not specified herein shall meet the regulations provided in Section 47-20. 5. Passenger loading areas shall meet the following: a. Location is limited to secondary and tertiary streets; b. One-way traffic movement with adequate width for by-pass lane; c. Areas designated for passenger loading and valet service shall be limited to twenty (20) percent of the building frontage. d. Covered passenger loading areas such as a port cochere are permitted with buildings that have a minimum length of one hundred fifty (150) feet and shall not exceed eighty (80) feet or twenty five (25) percent of the building frontage, whichever is less. 6. Bicycle parking and storage shall be provided as follows: a. Bicycle parking for short term use shall be installed as bike racks within fifty (50) feet of building entrance. b. Bicycle storage for long term use shall be provided within an enclosed, secure building space, with direct access to sidewalk or bike lane, and include racks for individual storage. c. Bicycle requirements are listed in Table 1. Table 1. Bicycle Parking and Storage Requirements Use | Short Term Bike Racks (number of spaces) | Long Term Bike Storage (number of spaces) Residential | 1/30 units | 1/5 units Commercial | 1/1,500 square feet of gross floor area | 25% of the required bike racks Restaurant, Café including outdoor dining areas | 1/750 square feet of gross floor area Office and Industrial | 1/10,000 square feet of gross floor area Civic and Institutional | 1/5,000 square feet of gross floor area Park and Open Space | 2/acre Parking Facilities | 1/25 vehicle parking spaces I. Parking structures. 1. Parking structures fronting primary and secondary streets shall meet the following: a. When fronting primary and secondary streets, the ground floor of structure must contain active uses for a minimum of seventy (70) percent of the frontage; b. Upper levels of the parking structure shall be screened from public view with liner units or active use or exceptional architectural screening or combination thereof, whereas the screening material can be architectural such as perforated metal, green screen system or planters whether live or artificial, or artistic elements such as murals; c. Parking structure stairwells shall be designed as an integral part of the structure with enhanced elements and enhanced stairwell top design; d. Access to the parking structure shall be from secondary street unless property fronts only primary street; e. Parking structure standards stated herein are not applicable to development in the UUV-SW and UUV-SC districts. f. Parking facades for parking structures that exceed two (2) stories and that front tertiary streets shall be screened a minimum of fifty (50) percent with architectural screening material. g. Parking structure facades that front parcel limits adjacent to Interstate 95 shall contain a minimum of fifty (50) percent screening material. Such screening material may vary in material type and may include creative illumination to create sense of place. Such illumination shall meet the requirements of subsection 47-37B.6.L. J. Streetscape zone. Streetscape zones shall contain an area for sidewalk and an area for street trees/furniture when fronting primary, secondary, and tertiary streets. 1. A minimum, unobstructed sidewalk width of seven (7) feet, 2. A minimum five (5) foot wide area for tree placement and furniture or other elements such as low seating walls, waste receptacles, bus shelters, bike racks or similar elements; 3. Streetscape zones are required as part of a development abutting right-of-way and where necessary shall extended onto private property with a sidewalk easement. K. Signage. Signage shall meet the regulations provided in Section 47-22, Sign Requirements, except as provided herein. 1. Ground signs are not permitted within the streetscape zone as described in Section 47-37B.6.J. Such signs shall not exceed five (5) feet in height and shall not exceed a total height of eight (8) feet above the natural grade is exceeded. 2. Projecting signs shall not exceed three (3) feet from the building wall and not exceed twelve (12) square feet in area. Such signs are permitted to encroach into the streetscape zone area and must maintain a nine (9) feet clearance from the bottom of the sign to the sidewalk or walkway below. 3. Creativity in sign design and material is encouraged as described in the Illustrations of Design Standards. L. Sense of place elements. Development projects are encouraged to incorporate creative design elements into their design. Such elements should be an artistic and functional component of a development project and the overall Uptown Project Area. Sense of place elements are required for projects within the Uptown Project Area and for key gateway properties. Building illumination should also be encouraged as a sense of place element. Future branding of the area should also focus on creating a unique visual representation of Uptown Project Area.

(Ord. No. C-19-34, § 3, 11-5-19; Ord. No. C-25-14, § 2, 4-15-25)

Ask a question about Fort Lauderdale law

Corpus searches the Fort Lauderdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.