§ 16-18V.011 — Relationship of building to street
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-18V.011
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/6c45154e-c215-4af2-ae62-694962c2356f
Sec. 16-18V.011. - Relationship of building to street.
1. The regulations in this section shall apply to all buildings and structures, including parking structures, adjacent to a required sidewalk or provided supplemental zone having a habitable space with a finished floor not more than five feet above or below the adjacent sidewalk. Such floor or floors shall be considered the sidewalk-level. See Diagrams 3 and 4. 2. Active uses: shall be required within buildings at sidewalk-level along Memorial Drive, Martin Luther King Jr. Drive, Capitol Avenue, Hill Street (south of Martin Luther King, Jr. Drive), Cherokee Avenue, and Boulevard, and along portions of local streets directly adjacent to Oakland Cemetery or a public park, except at ingress and egress points into parking structures or loading areas. For the purposes of this chapter active uses shall be serviced by plumbing, heating, and electricity and are limited to residential, retail, eating and drinking establishments, museum, gallery, office, institutional, auditorium, library, hotel lobby, or cultural facility uses, and shall not include parking, non-residential storage areas, driveway or queuing lanes parallel to the adjacent street. Minimum active use depths from the street-facing building façade shall be provided as follows: a. Single-family, two-family or multi-family residential buildings with no residential units located above or below a unit: Minimum depth of ten feet. b. All other uses (as specified above): Minimum depth of 20 feet. See Diagram 3. c. When two or more floors meeting the definition of sidewalk-level exist within the same building, this requirement shall only apply to the frontage of each floor located within five vertical feet above or below the grade of the adjacent sidewalk. See Diagram 4. 3. Minimum building façade height and floor delineation: The street-facing building façade shall rise vertically at the back of the required sidewalk or provided supplemental zone for the minimum building façade height as indicated on the SPI-22 Memorial Drive/Oakland Cemetery Development Controls Table. Building floors shall be delineated above sidewalk-level through windows, belt courses, cornice lines or similar architectural detailing. 4. Minimum sidewalk-level floor to ceiling height: shall be 12 feet for non-residential uses. See Diagram 3. 5. Minimum building frontage: a. Building façades shall be built to the back of and predominantly parallel to the required supplemental zone (as applicable) or sidewalk clear zone adjacent to Memorial Drive, Martin Luther King Jr. Drive, Capitol Avenue, Hill Street (south of Martin Luther King Jr. Drive), Cherokee Avenue, and Boulevard, for a minimum of 80 percent of the length of said supplemental or sidewalk clear zone. This shall not be construed as meaning that the building façade may not be articulated for doors, storefront windows, columns, or similar architectural features which may be recessed from the back of the required sidewalk a maximum depth of 18 inches from the façade to allow for articulation. b. Doors may be recessed from the back of the building façade as follows: i. Lobby doors and associated entries may be recessed a maximum depth of ten feet. ii. Vehicular doors may be recessed a maximum depth of 20 feet. iii. Other doors may be recessed a maximum depth of five feet. 6. Pedestrian entrances to all sidewalk-level uses with public or private street frontage: a. Shall be architecturally articulated, face, be visible from, and be directly accessible from the sidewalk adjacent to such street. b. When located along Memorial Drive, Martin Luther King Jr. Drive, Hill Street (south of Martin Luther King Jr. Drive), Cherokee Avenue, or Boulevard, shall face, be visible from, and be directly accessible from the sidewalk along one such street, with the exception of single-family and two-family dwellings and multi-family buildings with no unit located above or below another residential unit. c. The use of fire-escape, entrance-only and exit-only doors as primary entrances is explicitly prohibited. d. Having non-residential uses: i. Shall remain unlocked during business hours. ii. Shall be at-grade with the closest portion of the adjacent required sidewalk. e. Having residential uses: i. Shall be linked to the required sidewalk with a pedestrian walkway a minimum of four feet wide. ii. All such buildings, except assisted living facilities, with more than four residential units that are adjacent to the required sidewalk shall have individual entrances to such units directly accessible from the adjacent sidewalk and shall open directly onto the adjacent sidewalk, park, plaza or terrace adjacent to the sidewalk unless existing topographic considerations render this requirement unreasonable. All pedestrian walkways providing such access shall be perpendicular to the street, unless existing topographic considerations render this requirement unreasonable, and shall be permitted to share said walkway with one adjacent unit. iii. Said buildings shall have porches or stoops or wheelchair access at each sidewalk-level pedestrian entrance. iv. All residential uses not located at sidewalk-level shall have pedestrian access to the sidewalk via a common lobby fronting and accessible from said sidewalk. f. Shall have a visible and accessible push button activator seen from the clear zone sidewalk connected with a minimum five foot wide pedestrian walkway, except for those entrances that are used solely for access to an individual dwelling unit. This provision shall not apply to single-family and two-family residential structures. 7. Fenestration requirements: Buildings shall provide either a storefront façade treatment or a residential façade treatment along all street-fronting sidewalk-levels which shall apply to all uses including parking decks, except churches and fire stations and have the following requirements: a. Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less. Painted glass, reflective glass or other similarly treated or opaque windows are not permitted. b. Fenestration, including entryways, shall be provided for a minimum horizontal linear percentage for each façade specified below in subsection 16-18V.011(7)(c) and subsection 16-18V.011(7)(d). c. Storefront façade treatment: Adjacent to Memorial Drive, Martin Luther King Jr. Drive, or Capitol Avenue or other buildings on other streets having commercial uses at sidewalk-level, a storefront façade shall be required for a minimum of 65 percent of the horizontal length of the sidewalk-level façade per the following requirements (See Diagram 5): i. The length of façade without intervening fenestration or entryways shall not exceed 20 horizontal linear feet. ii. A minimum of 90 percent of the required fenestration shall allow visibility into habitable space for a minimum depth of ten feet from the interior window pane. The remainder of provided fenestration shall allow visibility for a minimum depth of three feet measured similarly. iii. Beginning at a point not higher than three feet above the adjacent sidewalk to a height no less than ten feet above the finished floor elevation when the finished floor elevation is less than three [feet] above the sidewalk. iv. Beginning at the finished floor elevation to a height no less than ten feet above the finished floor elevation when the finished floor elevation is three or more feet above the sidewalk. v. From its base to a height not less than the height of the adjacent primary pedestrian entrance, fenestration described in subsection iii. and iv. above shall be a single piece of plate glass having a minimum width of two feet. d. Residential façade treatment: Along all streets, except Memorial Drive, Martin Luther King, Jr. Drive, Capitol Avenue, and George Street, a residential façade treatment shall be provided for sidewalk-level residential uses for a minimum of 25 percent of the length of the sidewalk-level façade with each façade being calculated independently, in addition to the following requirements: i. Windows on each street frontage façade shall be a minimum three feet in height and substantially similar in size on all sidewalk-level façades. ii. Equally sized vertical windows shall be arranged horizontally. iii. Windowpanes shall be recessed a minimum two inches from the adjacent façade. 8. External storefront security grilles, gates and security doors: shall be fully retractable during business hours and shall permit visibility into the interior of protected space when in use. External housing and shields for such systems shall be painted the same color as the frames of the storefront system they protect. 9. A street address number shall be located directly above or beside the primary building and business establishment entrances along the required sidewalk, shall be clearly visible from the sidewalk and shall be a minimum of six inches in height. 10. Awnings and canopies: Shall not encroach beyond the sidewalk clear zone. 11. Sidewalk arcades: Arcades shall be prohibited. 12. Fences and walls: Shall meet the following regulations: a. For residential uses adjacent to the sidewalk: fences shall not exceed four feet in height when located between the primary building and the street. b. For non-residential uses adjacent to the sidewalk: fences are prohibited when located between the building and the sidewalk except where specifically authorized elsewhere in this chapter for outdoor dining. c. For non-residential uses not adjacent to the sidewalk: Fences and walls located between the primary building and the lot line and not exceeding six feet in height may be erected but shall not be permitted between the primary building and the street except as set forth below in subsection 16-18V.011(12)(d). d. No walls, except retaining walls, shall be located between the street and any building, with the exception of screening for authorized off-street loading areas. e. Retaining walls located adjacent to a sidewalk along a public or private street shall not exceed a height of 36 inches and the combined height of a fence and retaining wall shall not exceed a height of six feet, unless existing topographic considerations render this requirement unreasonable. Retaining walls shall not be finished with split-faced concrete or cinderblock. See subsection 16-29.001(25). f. No chain link fence or similar elements shall be visible from any public plaza, ground-level or sidewalk-level outdoor dining area or public right-of-way. No barbed or razor wire fence shall be permitted. 13. Associated vehicular services such as air pumps and car washes shall not be located between a building and the street.
(Ord. No. 2006-96, § 1(Att. A), 12-6-06; Ord. No. 2026-05(26-O-1001), § 14, 2-25-26)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.