For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 16-20M.013 — Architectural standards

Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-20M.013

Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/f90eb52a-6a81-4f43-a3bb-abeaa4bd80a1

Sec. 16-20M.013. - Architectural standards.

(1) Statement of intent. The purpose of these regulations is to set forth basic, minimum standards of architectural design and construction that are compatible with and complementary to the existing historic residences within the neighborhood, as the cumulative historic diversity of the built environment is a defining characteristic of this neighborhood. It is not the intent of these regulations to limit the design of new housing to replication of styles of existing structures, but to foster residential design that, with regard to massing, size, scale, materials, and architectural elements, enhances the architectural quality of the neighborhood and simultaneously encourages creativity. Additionally, these regulations are intended to integrate the physical characteristics of new construction into the existing neighborhood in a meaningful way so as to restore and promote the public health, safety, and welfare of this neighborhood. The following residential architectural styles currently predominate in the neighborhood and contribute to its unique historic character; they are included here for reference only: American Four Square, Craftsman, English Vernacular Revival, Folk Victorian, Queen Anne, and Minimal Traditional Cottages. (2) Design standards and criteria for new principal structures. (a) No individual house design shall substantially repeat a design of a new principal structure on the block face that was approved by the commission since the adoption of this district. (b) An unpaved planting strip adjacent and parallel to the public street shall be provided. The compatibility rule shall apply to the dimensions and design of planting strips. (c) A sidewalk between the planting strip and the required front yard and parallel to the public street shall be provided. The sidewalk shall be the same width as the sidewalk on abutting properties or it shall be the width otherwise required by city ordinance, whichever is greater. If no sidewalk exists in the block, the new sidewalk shall not be less than six-feet wide. The compatibility rule shall apply to sidewalks paving materials. If no sidewalk paving material predominates in the block, the sidewalk shall be constructed of the historically accurate material for that block, either hexagonal pavers, concrete inlaid with hexagonal imprint, or brick. (d) A paved walkway from the front sidewalk to the front entry of the principal structure shall be provided. (e) All front façades, front porches, and front doors of the principal structure shall face and be parallel to the street, except in those blocks in which the historic pattern is such that houses are situated at an angle to the street, in which case the compatibility rule shall apply. (f) The compatibility rule shall apply to the form and pitch of the primary roof of the primary structure. (g) The compatibility rule shall apply to the height, scale, and massing of the principal structure. In no case shall the height of a structure exceed 35 feet. (h) The maximum height of the first floor of the front façade above grade shall be subject to the compatibility rule. At a minimum, the first floor of the principal structure shall be on foundations and shall be elevated above grade at the front façade a minimum of two entrance risers each of which shall not be less than seven inches in height. Slab-on-grade construction is not permitted. (i) The compatibility rule shall apply to the design and size of front porches, and the placement and orientation of front steps. Front porches shall contain roofs, balustrades, columns, steps, and other features as determined by the compatibility rule. Front porches may extend up to ten feet into the required front yard. All front porch steps shall have closed risers and ends. (j) Decks are permitted only when located to the rear of the principal structure and such decks shall be no wider than the width of the principal structure. (k) The use of chimneys with new principal structures is encouraged. When any portion of a chimney is visible from a public street as a façade element, the chimney shall originate at grade. (l) Fences and walls, excluding retaining walls, visible from a public street upon completion, subject to provisions of section 16-28.008(5) and the following limitations, may occupy required yards: 1. Fences not exceeding four feet in height may be erected in the front yard or half-depth front yard. Walls, excluding retaining walls, are not permitted in the front yard or half-depth front yard. 2. Fences and walls, excluding retaining walls, not exceeding six feet in height may be erected in side or rear yards. 3. The compatibility rule shall apply to the design of all fences located in a front yard or half-depth front yard. Fences located in the front yard or half-depth front yard shall be constructed of brick, stone, ornamental iron, or wood. Chain link fencing is not permitted in front yards or half-depth front yard. (m) The compatibility rule shall apply to the design and height of portions of retaining walls located in a front yard or half-depth front yard that are visible from a public street. Such retaining walls shall be faced with stone, brick, or smooth stucco. The compatibility rule notwithstanding, at no point of such retaining wall shall exceed four feet in height. (n) Fenestration, if visible from a public street upon completion, shall meet the following requirements: 1. Windows in the front façade shall be predominantly vertical in proportion. 2. If muntins or mullions are used, such muntins or mullions shall be either true divided lights or simulated divided lights with muntins integral to the sash and permanently affixed to the exterior face of glass. (o) Window and door casing widths and depths: 1. Replacement windows units shall maintain the size and shape of the original window opening. 2. The compatibility rule shall apply to the following aspects of fenestration: a. The size and shape of individual window openings. b. The overall pattern of fenestration as it relates to the building façade. c. The style of the individual window. (p) Mechanical and communication equipment shall be located to the side or rear of the principal structure and in the location least visible from a public street. Screening with appropriate plant material or fencing is required if the equipment is visible from a public street. (q) Subject to the compatibility rule, wood or smooth-finish cementitious lap siding, wood shingles, brick, stone, and true stucco are permissible building materials for the façades of the principal structure. Corrugated metal, aluminum siding, and vinyl siding are not permitted. (r) In addition to all other applicable regulations, the compatibility rule shall apply to the following building materials and design elements, if visible from a public street upon completion: 1. The dimensions of the exposed face of lap siding and wood shingles. 2. The type of brick and pattern of brickwork. 3. The type of stone and pattern of stonework. 4. The material and texture of stucco. 5. The size and type of exterior doors. Notwithstanding the compatibility rule, exterior doors shall be wood panel or fixed glass panel in wood frame. 6. The materials and pattern of roofing. 7. Gables and gable returns. 8. Dormers 9. Paving materials for walks and drives. 10. Above-grade foundation materials. Notwithstanding the compatibility rule, foundations shall constitute a distinct building design element and shall contrast with the primary façade's exterior material and exposed concrete or concrete masonry unit (CMU) foundation walls are prohibited as a finished surface. 11. Exterior portions of chimneys. Notwithstanding the compatibility rule, chimneys shall be faced with masonry and siding on chimneys is not permitted. 12. The location and design of skylights. Notwithstanding the compatibility rule, when practical, skylights should be located where least visible from the public street. If skylights are visible from the public street, the glass shall be tinted to match the surrounding roof area. Protruding "bubble" skylights are prohibited.

(Ord. No. 2003-102, § 3(Att. C), 11-10-03)

Ask a question about Atlanta law

Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.