§ 16-18P.014 — Relationship of building to street
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-18P.014
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/6a23d3c8-14e7-4ea4-a18c-6a0c04622abd
Sec. 16-18P.014. - Relationship of building to street.
1. For purposes of this chapter, sidewalk level shall be defined as any floor of a building with a finished-floor elevation less than or equal to five feet above and below the adjacent sidewalk (or street if no sidewalk is existing). 2. Building floors shall be delineated from the third story above sidewalk level down to each sidewalk level and shall be executed through windows, belt courses, cornice lines and/or similar architectural detailing. 3. General sidewalk level building façade requirements: a. All buildings shall have a minimum 24-foot façade height along the public right-of way and shall have a minimum of one building façade meeting the primary sidewalk-level building façade requirements of this Section; b. Active uses along existing and new streets shall be provided as delineated in Table 5: SPI-16 Street Activation Table, to a minimum depth of 40 feet for non-residential uses and 20 feet for residential uses beginning at any sidewalk level street facing building façade to a minimum height of 20 feet above sidewalk level except when topographical conditions prevent such treatment. These active uses shall be internally illuminated and serviced by plumbing, heating, and electricity and are limited to uses set forth in Table 5: SPI-16 Street Activation Table, with the following exceptions which also shall be allowed: i. Fire command and transformer (or similar electrical) rooms, each not exceeding ten feet of street fronting façade length. For parcels with more than one street frontage, such room(s) shall be located on the lesser classified street(s) according to Attachment C Street Typology Map; and ii. Structures required for public transit; c. The primary street fronting pedestrian entrance for sidewalk level uses: i. Shall face, be visible and be accessible with a push button activator seen from the clear zone sidewalk connected with a minimum of five feet wide pedestrian walkway; and ii. Shall have a minimum six-inch-high street address located directly near the primary building entrance clearly visible from the sidewalk; d. Residential uses which do not have street frontage shall be linked to the public sidewalk with a minimum four feet wide pedestrian walkway. e. Accessory residential uses (such as lobbies, clubhouses, mail rooms and similar) at the sidewalk level along type A streets shall be limited to the greater of either: 40 feet of street frontage; or 50 percent of the overall street fronting façade length. Any bike room shall be located on the lesser classified street(s) according to Attachment C Street Typology Map and limited to 20 feet of such street frontage length. 4. Fenestration requirements. Street-fronting sidewalk level building façades, except places of worship, fire stations & MARTA uses, shall meet the following requirements: a. Length. Fenestration and entrances shall be provided for a minimum of the horizontal length of each street-fronting sidewalk-level façade, as designated in the Table 5: SPI-16 Street Activation Table. The length of façade without intervening fenestration or entryways shall not exceed 20 feet; b. Surface treatment and visibility. Windows and door glass shall utilize clear glass or tinted glass. Tinted glass shall have a transmittance factor of 50 percent or greater and shall have a visible light reflectance factor of ten or less having visibility into the building for a minimum depth of ten feet as measured from the interior windowpane. Painted glass, reflective glass or other similarly treated or opaque windows are prohibited. c. Non-residential uses. Fenestration and entrances shall be-measured beginning at a point not more than 36 inches above the required sidewalk to a height at least ten feet above said sidewalk unless: i. When the finished floor elevation is 36 or more inches above the sidewalk: Beginning at the finished floor elevation to a height at least ten feet above the finished floor elevation; or ii. When the finished floor elevation is below said sidewalk: Beginning at a point not higher than six inches above the adjacent sidewalk to a height at least ten feet above the finished floor elevation. d. Residential uses. Fenestration and entrances shall have windows at a minimum of four feet in height. Table 5: SPI-16 Street Activation Table Street Typology | Location | Permitted Active Uses (as further regulated in Table 1: SPI-16 Table of Uses) | Min. Fenestration (as % of street level façade) A1 Street | Peachtree St from 5th St to 15 th St | Places of worship, Eating & Drinking Establishments, Hotels & Motels 1 , Multi-family/ Duplexes/ Single-Family Dwellings 1 , Museums/Galleries/Libraries, Offices 1 , Medical/Dental Office 1 , Retail Establishments | 75% for all uses A2 Street | North Ave, 5th St, 10th St, 12th St from Williams St to Juniper St, 14th St from Williams St to Juniper St, 17th St, Spring St from North Ave to 17th St, West Peachtree St from North Ave to 17th St, Crescent Ave, Peachtree St from North Avenue to 5 th St, Peachtree St from 15th St to I-85 | All uses allowed on type A1 Streets, Banks/Financial Institutions, Barber Shops & Beauty Shops, Business/Commercial Schools, Childcare Centers, Clubs/Lodges, Commercial Recreation, Institutions of Higher Learning, Laboratories and Research Facilities, Laundry/Dry Cleaning, Professional/ Personal Services, Public & Private Schools, Sales & Repair Establishments, Veterinary | 65% of all uses B1 Street | Juniper St from 13th St to 14th St and Juniper St from North Ave to 10th St | All uses allowed on type A Streets, Dormitories/Fraternities/Sororities, Nightclub/Lounge, Fuel Service Stations, Mortuary/Funeral Homes, Nursing Homes/ Personal Care Homes/Assisted Living Facilities/Rehabilitation Centers, Printing, Service Stations, Shelters, Supportive Housing | 50% for non-residential uses, 30% for residential uses B2 Street | Ponce De Leon Ave, 3rd St, Biltmore Pl, 6th St, 7th St, Peachtree Pl, 12th St from Juniper St to Piedmont Ave, 14th St from Juniper to Piedmont Ave, 15th St from Spring St to Peachtree Cir, Spring St from 17th to Peachtree St, West Peachtree St from 17th St to Peachtree St, Beverly Rd to Inwood Cir, Peachtree Walk from 10th St to 13th St, Cypress St from 3rd St to Peachtree Pl, Piedmont Ave from Ponce de Leon Ave to 3rd St C Street | Other existing streets not listed | Active Uses not required | 30% for all 1 Limited 40 feet of street frontage for each use, provided that the sum of all such uses shall not exceed 50 percent of the overall street fronting façade length along a type A1 street.
(Ord. No. 2017-56(17-O-1401), § 1(Exh. 1), 10-2-17; Ord. No. 2018-17(18-O-1070), § 5, 6-13-18; Ord. No. 2022-25(22-O-1496), § 2, 8-24-22; Ord. No. 2024-22 (23-O-1709), § 1, 6-26-24)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.