§ 16-18A.020 — Specific regulations for Subarea 6 (Terminus) and Subarea 7 (Fairlie-Poplar)
Atlanta City Code (Code of Ordinances, Part II) (Supp. No. 108, Update 1: codified through Ordinance No. 2026-37 (26-O-1511), enacted September 30, 2026) · Atlanta Land Development Code § 16-18A.020
Corpus is an independent public-information project, not the official City of Atlanta website. Stable reference: corpuslaw.us/code/94ad4333-9bec-4d06-8043-a31307215dad
Sec. 16-18A.020. - Specific regulations for Subarea 6 (Terminus) and Subarea 7 (Fairlie-Poplar).
The following regulations shall apply to Subarea 6 (Terminus) and Subarea 7 (Fairlie-Poplar) otherwise as specified: 1. [Application.] An application for special administrative permits shall be submitted to the Atlanta Urban Design Commission (AUDC) staff for review and report prior to any final action on such application when any variations from this section are requested. AUDC staff review and report shall include, but not be limited to, the proposed improvement's visual impacts on the existing building and/or surrounding buildings or structures. 2. Building façades: See section 16-18A.020 Diagram 7. a. Buildings equal or less than seven floors shall have façades divided into three distinct horizontal parts as follows: i. A base, which shall include the sidewalk-level. ii. A shaft, which shall include the second floor through the bottom one-half of the floor immediately below the top floor. iii. A cap, which shall include a belt course located at the line defining the top one-half of the top floor or a cornice located on a parapet wall above the top floor. b. Buildings with eight or more floors shall have façades divided into three distinct horizontal parts as follows: i. A base, which shall include the sidewalk-level and the second floor, but shall not extend above the third floor. ii. A shaft, which shall extend from above the base, but shall not extend into the top floor of the building. iii. A cap, which shall, at a minimum, include the top floor and may include up to the top three floors. c. Within the shaft, windows shall be subject to the following: i. Shall be equal in size. ii. Shall be greater in height than width. iii. Shall be arranged in a grid pattern. iv. The total surface area of the street-fronting façade treated as windows shall be between 45 percent and 85 percent. 3. Balconies: See section 16-18A.020 Diagram 8. 1. Street-facing balconies: In the Subarea 7, shall not extend greater than 18 inches beyond the building façade and shall not be inset greater than 18 inches into the façade. 2. Non-street facing balconies sidewalk shall not have any requirements. 3. The underside of balconies shall not have exposed wood framing. 4. Awnings and canopies: 1. Shall be cloth, canvas, metal or glass. 2. Shall not be internally lit. 3. Shall be directly above a window or storefront and shall reflect the shape of the window or storefront. 5. Windows: a. Street facing windows shall be one of the following types: True divided, simulated divided, or one-over-one. Flat "snap-in" muntins and mullions and those between layers of glass are prohibited. b. Windows, including display windows, but not transoms, shall be greater in height than in width. c. When dropped ceilings are located below the head of a window, display window or transom at sidewalk-level: Shall be recessed a minimum of 18 inches from the window opening. d. Street facing windows not located at sidewalk-level shall be subject to the following: i. Shall include sills of masonry, stone, cast stone, or terra cotta. ii. Shall include windowpanes recessed a minimum of three inches from the adjacent façade. 6. Façade treatment: a. Street-facing façades: Shall be brick, cast stone, unpolished or unpainted stone or unpainted terra cotta. b. Street-facing cornices, wall details and decorations: Shall be brick, stone, cast stone, terra cotta, or painted metal except that cornices, wall details and decorations located at a height greater than 45 feet above the required sidewalk may be fiberglass or composite materials. Cornice lines: Shall be predominantly horizontal in character. c. Non-street facing façades: Shall be brick, cast stone, unpainted stone, unpainted terra cotta, stucco, or concrete masonry units, with the exception of widows and openings in parking structures. 7. Storefront streets. Storefront streets shall meet the following regulations in addition to section 16-18A.012: a. All sidewalk-level pedestrian doors shall be 70 percent clear glass, which shall not utilize painted glass, reflective glass or other similarly treated or opaque windows. b. All storefronts shall consist of components of equal length, vertically stacked, and as follows: (See section 16-18A.020 Diagram 7): i. A non-glass bulkhead or knee wall beginning at grade and extending to a point between 18 inches and 24 inches above the sidewalk. ii. A glass display window beginning at the top of the bulkhead or knee wall, to a height between ten feet and 11 feet above said sidewalk. iii. A glass transom located above the glass display window and sidewalk-level door and having a minimum height between 18 inches and 36 inches. 8. Subarea 7 (Fairlie-Poplar) additional requirements. Subarea 7 (Fairlie-Poplar) additional requirements (see section 16-18A.020 Diagram 9: Façades, not including doors, may be recessed from the back of the required sidewalk a maximum depth of 18 inches to allow for articulation. 9. Subarea 7 (Fairlie-Poplar) for additional illustrations and recommendations: See the Fairlie-Poplar: The Heart of Atlanta—Design Guidelines which can be obtained from the Atlanta Urban Design Commission (AUDC).
(Ord. No. 2007-71(07-O-2221), § 1(Att. A), 11-27-07)
Ask a question about Atlanta law
Corpus searches the Atlanta sections it holds and shows the ones that match, with their citations. Free, no sign-in.
