§ 9-1A-53 — IBC BUILDING CODE AMENDMENT, SECTION 1605.2, LOAD COMBINATIONS USING STRENGTH DESIGN OR LOAD AND RESISTANCE FACTOR DESIGN, ADD EXCEPTION 3

City Code of Boise City, Idaho (2026 S-32: current through Ord. 38-26, passed 9-29-2026) · Boise City Code § 9-1A-53

Corpus is an independent public-information project, not the official City of Boise City website. Stable reference: corpuslaw.us/code/552fc325-8dee-491f-bb07-832919e46035

9-1A-53: IBC BUILDING CODE AMENDMENT, SECTION 1605.2, LOAD COMBINATIONS USING STRENGTH DESIGN OR LOAD AND RESISTANCE FACTOR DESIGN, ADD EXCEPTION 3:

Add exception 3 to section 1605.2 as follows: 3. In Equation 16-3, the snow load S shall be calculated using pm as defined in Section 1608.1. For other load combinations involving snow loads, S shall be calculated using flat roof snow load (pf) or sloped roof snow load (ps) as defined in ASCE 7. (Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)