§ 9-1A-55 — IBC BUILDING CODE AMENDMENT, SECTION 1608.1, SNOW LOADS
City Code of Boise City, Idaho (2026 S-32: current through Ord. 38-26, passed 9-29-2026) · Boise City Code § 9-1A-55
Corpus is an independent public-information project, not the official City of Boise City website. Stable reference: corpuslaw.us/code/0b95a90c-66f3-47f5-aa56-ccbd4b4cd117
9-1A-55: IBC BUILDING CODE AMENDMENT, SECTION 1608.1, SNOW LOADS:
1608.1 General. Design snow loads shall be determined in accordance with Chapter 7 of ASCE 7, but the design roof load, regardless of roof slope, shall not be less than a uniform snow load of pm = 25 psf. This minimum roof snow load is a separate load case. It need not be used in determining or in combination with drift, sliding, unbalanced, rain-on-snow surcharge, or partial loads. These loads shall be considered as required by ASCE 7 and IBC section 1608.2 as amended. See Figure A showing two examples of required load cases. FIGURE A [image omitted; see the official code] (Ord. 44-17, 12-19-2017, eff. 1-1-2018; amd. Ord. 39-20, 12-1-2020, eff. 1-1-2021)
Ask a question about Boise City law
Corpus searches the Boise City sections it holds and shows the ones that match, with their citations. Free, no sign-in.