§ 14B-15-1516 — Interior roof edge for shafts and fully enclosed courts
Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14B-15-1516
Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/6ada342e-c166-450f-a48a-72ddd5d1c1c8
14B-15-1516 Interior roof edge for shafts and fully enclosed courts.
The following language is adopted as a new Section 1516: “1516. LOW-SLOPED ROOF EDGES AND OPENINGS 1516.1 Scope. Low-sloped roofs shall comply with the applicable requirements in Sections 1516.2 and 1516.3. 1516.2 Roof edges adjoining shafts and fully enclosed courts. The edges of a low-sloped roof that adjoin a shaft or a court that is enclosed on all sides shall be provided with a parapet wall, extended masonry, or guard, or any combination thereof, that meets the requirements of Section 1015. 1516.3 Skylights and other openings. All skylights and other openings located in the plane of a low-sloped roof that are not otherwise required to remain open and unobstructed by law shall be either: (i) glazed with wired glass, plain glass, glass block, or polycarbonate plastic that is designed to meet the applicable live load requirements for the roof under Section 1607; or (ii) provided with a parapet wall, extended masonry, or guard, or any combination thereof, that meets the requirements of Section 1015.” (Added Coun. J. 10-9-24, p. 18818, § 1; Amend Coun. J. 6-17-26, p. 45214, Art. IV, § 35)
Ask a question about Chicago law
Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.