14B-30-3004 Other conveyance devices.

The provisions of Section 3004 of IBC are adopted by reference with the following modifications: 1. Revise Section 3004.1 to read: "3004.1 General. Conveyance devices, other than elevators, shall comply with the Chicago Conveyance Device Code and the provisions of Sections 3004.2 through 3004.4." 2. Delete the word "approved" in Section 3004.2. 3. Revise Section 3004.2.1 to read: "3004.2.1 Floor openings. Escalator floor openings shall comply with Section 712." 4. Revise Section 3004.3 to read: "3004.3 Conveyors. Conveyors and conveying systems shall comply with Chapter 10 of the Chicago Conveyance Device Code." 5. Revise Section 3004.3.1 to read: "3004.3.1 Enclosure. Conveyors and related equipment connecting successive floors or levels, other than on construction sites, shall be enclosed with shaft enclosures complying with Section 713." 6. Revise Section 3004.4 by replacing "an approved" with "a."