§ 14X-5-505.8.2 — Direction of swing

Municipal Code of Chicago (2026 S-74, current through Council Journal of June 17, 2026) · Municipal Code of Chicago § 14X-5-505.8.2

Corpus is an independent public-information project, not the official City of Chicago website. Stable reference: corpuslaw.us/code/e8b31072-c560-46f3-9ff3-428aa49dfee2

14X-5-505.8.2 Direction of swing.

Pivot or side-hinged swinging doors must swing in the direction of egress travel where serving an occupant load of 50 or more persons. Exception: In Group B occupancies, existing egress doors and replacement egress doors of the same size and configuration installed in the same location may swing opposite the direction of egress travel when opening onto a corridor and serving an occupant load of 100 or fewer persons. (Amend Coun. J. 1-26-22, p. 43756, Art. IV, § 1)

Ask a question about Chicago law

Corpus searches the Chicago sections it holds and shows the ones that match, with their citations. Free, no sign-in.