§ 5-1B-2 — AMENDMENTS:
Municipal Code of Naperville, Illinois (Supp. No. 101: codified through Ordinance No. 26-049, adopted May 19, 2026) · Naperville Municipal Code § 5-1B-2
Corpus is an independent public-information project, not the official City of Naperville website. Stable reference: corpuslaw.us/code/abfb03f6-036b-4535-b15e-ae67e9f1c4d6
5-1B-2: - AMENDMENTS:
The following requirements shall be applicable to one- and two-family dwellings and townhouses as stated above: Chapter 1 Administration R101.1 Title: Change to read: These provisions shall be known as the residential code for one- and two-family dwellings of the city of Naperville, and shall be cited as such and will be referred to herein as "this code." Add a new section as follows: R101.2. Scope: Change to read as follows. Exceptions: 1. Dwelling units that include permitted work area (see Zoning Code) of not more than 25% of the area of a dwelling unit are permitted to be built or classified as dwelling unit as defined by this code. PUD townhouse and duplex developments which have been approved by the city council prior to the adoption of the 2024 IRC shall be allowed to continue to use the 2018 IRC building code, or any code permitted by city council authority until the development is completed in its entirety. R105.2 Work Exempt From Permit. Building: Delete: Nos. 2, 3, 4, 5, and 7 Change to read as follows: 1. One-story detached accessory structures used as tool and storage sheds, playhouses and similar uses, provided the floor area does not exceed 150 square feet. Add the following: 11. Patios less than 500 square feet in size located in the rear yard will not require a permit, but must still follow all setback and easement restrictions. Additionally, if said patio includes any electrical, plumbing, or gas fixtures, a permit and inspections will be required. R105.3 Application For Permit: Add the following: 8. An application for permit must be accompanied with a signed and sealed legal plat of survey unless deemed not required by the Building Official. R105.3.2 Time Limitation Of Permit Application: Change to read: An application for a permit for any proposed work shall be deemed to have been abandoned 180 days after the date of filing unless such application has been pursued in good faith or a permit has been issued; except that the building official is authorized to grant one 30-day extension. The extension shall be requested in writing and justifiable cause demonstrated. R105.5 Expiration of Permit: Change to read: Every permit issued shall become invalid unless the work authorized by such permit is commenced within 180 days after its issuance, or if the work authorized by such permit is suspended or abandoned for a period of 180 days after the time the work is commenced. Every permit shall become invalid after a period of one year from the date of its issuance. Expired permits shall be subjected to additional plan review including new fees for such review as well as administrative fees for issuing said permit. The building official is authorized to grant, in writing, one or more extension of time, for periods not more than 180 days each. The extension shall be requested in writing and justifiable cause demonstrated. R106.1.1 Information On Construction Documents: Change to read as follows: The maximum size of construction documents shall be limited to 36" x 24" paper unless approved by the building official. Construction documents shall be drawn upon suitable material. Construction documents shall be of sufficient clarity to indicate the location, nature and extent of the work proposed and show in detail that it will conform to the provisions of this code and relevant laws, ordinances, rules and regulations, as determined by the building official. Where required by the building official, all braced wall lines, shall be identified on the construction documents and all pertinent information including, but not limited to, bracing methods, location and length of braced wall panels, foundation requirements of braced wall panels at top and bottom shall be provided. An approved copy of the construction documents in an electronic media (PDF format) are to be submitted prior to the issuance of the final occupancy. R106.1.4 Information For Construction In Flood Hazard Areas: Change to read: For buildings and structures in flood hazard areas as established on local flood insurance rate maps, locally adopted floodplain ordinances shall apply. 109.1.6.1 Elevation documentation. Change to read as follows: If located in a flood hazard area, provide documentation per the requirements of the county the project was built. Add the following: 109.1.6.2 Elevation and as-built site plan: Where a grading plan and/or engineering plans were submitted per the application requirements, an as-built grading and/or engineering plan must be submitted before a certificate of occupancy can be issued. R110.4 Temporary Occupancy: Change to read as follows: The building official is authorized to issue a temporary certificate of occupancy before the completion of the entire work covered by the permit, provided that such portion or portions shall be occupied safely. A temporary occupancy up to 60 days may be granted by the City from April 16 through September 30, and an extended temporary occupancy may be granted by the city from October 1 through April 15, but shall expire no later than the first June 15 following the temporary occupancy approval. Prior to issuance of a temporary certificate of occupancy, a cash deposit shall be posted with the City to guarantee completion of the entire work covered by the permit. The cash deposit shall be posted in an amount equal to one half of one percent (0.50%) of the value of the permitted improvements, but shall in no case be less than two thousand dollars ($2,000.00). The full value of the cash deposit shall be returned to the depositor or the depositor's designee following the issuance of the certificate of occupancy. Should the certificate of occupancy not be issued within twenty-four (24) months of the issuance of the temporary certificate of occupancy, the cash deposit shall be forfeited and retained by the City. In the case of a forfeiture, the requirement for a certificate of occupancy shall continue and be subject to enforcement by the City. R113.4 Violation Penalties: Change to read: Any person who violates a provision of this code or fails to comply with any of the requirements thereof or who erects, constructs, alters or repairs a building or structure in violation of the approved construction documents or directive of the building official, or of a permit or certificate issued under the provisions of this code, shall be subject to penalties as prescribed by law and/or subject to permit fees, including double the cost for inspections and administrative fees as outlined in title 1, chapter 9, article H, Fees For Construction, in the Naperville municipal code, and shall be subject to a stop work order until such time a permit is obtained. Chapter 2 Definitions: Add the following: Bedrooms: A private room planned and intended for sleeping, separated from other rooms by a door. A bedroom will have windows, closet and is physically separate from other rooms. Large Room Addition: A building addition that increases the existing gross floor area as defined in Chapter 2 of the 2012 International Building Code of the principal structure by 50% or more. Partial Razing — New Construction: When 50% or more of a dwelling unit is razed, for which a razing permit is required, the owner shall be required to obtain a new construction permit for any replacement work done and shall cause the entire building to conform to the requirements set forth in title 5 of this code. When it is necessary for a new construction permit to be obtained as set forth herein, the site control provisions set forth in section 5-2B-8 shall apply. Registered Design Professional: A duly licensed architect or structural engineer in the state of Illinois. Chapter 3 Building Planning: Ground Snow Load | Wind Design | Seismic Design Category | Subject to Damage From | Winter Design Temp | Ice Barrier Underlayment Required | Flood Hazard | Air Freezing Index | Mean Annual Temperature Speed (mph) | Topographic Effects | Special Wind Region | Windborne Debris Zone | Weathering | Frost Line Depth | Termite 30 | 115 mph (nominal design 3-second | No | No | No | A | Severe | 42 inches | Moderate to Heavy | -4 degrees F | Yes | Refer to Local | 1635 | 48.7 degrees F Elevation | Latitude | Winter Heating | Summer Cooling | Altitude Correction Factor | Indoor Design Temperature | Design Temperature Cooling | Heating Temperature Difference | Cooling Temperature Difference | Wind Velocity Heating | Wind Velocity Cooling | Coincident Wet Bulb | Daily Range | Winter Humidity | Summer Humidity 706 * | 41 | -1 | 91 | 0 | 72 degree F Maximum | 75 degree F Minimum | 73 degrees F | 16 degrees F | 8.4 mph** | 5.7 mph** | 76 | Medium (16-25 degrees) | 30% | 50% * Manual J, Residential Load Calculation, ACCA, Eighth Edition, Version 2, Aurora ** https://www.isws.illinois.edu/statecli/wind/wind.htm, Table 1, State Climatologist Office for Illinois R306 Flood Resistant Construction: Delete in its entirety R308.1 Premises Identification: Change to add the following: Buildings shall be provided with approved address identification. The address identification shall be legible and placed in a position on the building that is visible from the street or road fronting the property. Address identification characters shall contrast with their background. Address numbers shall be Arabic numbers or alphabetical letters. Numbers shall not be spelled out. Each character shall be a minimum of 5½" high with a minimum stroke width of 0.5 inch (12.7mm). Where required by the fire code official, address identification shall be provided in additional approved locations to facilitate emergency response. All multi-tenant commercial buildings and multi-family residential dwelling units shall have additional address numbering placed on the rear door, if appropriate, with the same requirements noted above. Exception: detached residential garages. Address identification shall be maintained. R309.2 One- and two-family dwellings automatic fire systems. Changed to read as: An automatic residential fire sprinkler system shall be installed in one- and two-family dwellings. Exceptions: 1. An automatic residential fire sprinkler system shall not be required for additions, alterations or accessory structures to existing buildings that are not already provided with an automatic residential sprinkler system. 2. An automatic residential fire sprinkler system shall not be required for new construction when all the following apply: a. Underside of all interior stairs are protected with at least .5 inches gypsum board or equal. b. Each one- and two-family dwelling unit has at least 2 means of egress. R310 Smoke Alarms: Add a new section to read as follows: R310.6 Exception 2 Smoke Alarms, Power Source: Modify section to read as follows: Smoke alarms in the portion of the residence that is not impacted by the renovation or addition installed in accordance with Section R314.2.2 shall be permitted to be battery powered. Smoke alarms within the area of renovation or addition shall follow power source requirements as identified in R310.6. Add new subsections to read as follows: R310.8 Fire Alarm And Detection Systems Fire alarm and detection systems for townhouses shall be installed in multiple single-family dwellings (townhouses), if the building or structure contains three (3) or more units. All fire alarm and detection systems shall be listed and installed in accordance with the provisions of NFPA 72, the IBC 2024, the IFC 2024, and the current edition of the Naperville fire department's regulations for the installation, maintenance, and testing of fire alarm systems, as amended from time to time. R311.1 Carbon monoxide alarms: Change to read as follows: For new construction, an approved carbon monoxide alarm shall be installed outside and within 15 feet of each separate sleeping area in the immediate vicinity of the bedrooms in dwelling units within which fuel-fired appliances are installed and in dwelling units that have attached garages. R311.4 Single And Multiple Station Carbon Monoxide Detectors: All carbon monoxide detectors shall be installed in accordance with the provisions of manufacturer's installation instructions. R311.6 Exception 2 Carbon Monoxide Alarms, Power Source: Modify section to read as follows: Carbon monoxide alarms installed in the portion of the residence that is not impacted by the renovation or addition installed in accordance with Section R311.2.2 shall be permitted to be battery powered. Carbon monoxide alarms within the area of renovation or addition shall follow power source requirements as identified in R311.6. R313.1 Minimum Height: Add Exception 5. Exception 5. Habitable spaces created in existing basements shall have ceiling heights of not less than 6 feet 8 inches, except that the ceiling height at obstructions shall be not less than 6 feet 4 inches from the basement floor. Existing finished ceiling heights in non-habitable spaces in basement shall not be reduced. Add new subsections to read as follows: R314.8.1 Non-Monitored Fire Alarm Systems: Townhouses equipped with existing fire alarm systems which are not currently monitored in accordance with the Naperville fire department requirements for the installation, maintenance, and testing of fire alarm systems shall be monitored in accordance with the Naperville fire department requirements for the installation, maintenance, and testing of fire alarm systems. R317.3 Flood Hazard Areas: Delete in its entirety. R319.1 Emergency Escape and Rescue Openings: Delete Exception 3. R319.7 Alterations or Repairs of Existing Basements: Delete in its entirety. Add a new section to read as follows: R322.4 Visitability. Add new sections #4, 5, 6 to read as follows: 1. Wall Reinforcement. One first floor bath shall be provided with wood blocking installed within wall framing, to support grab bars as needed. The wood blocking, when measured to the center, shall be located between thirty-three (33) inches and thirty-six (36) inches above the finished floor. The wood blocking shall be located in all walls adjacent to a toilet, shower stall or bathtub. 2. Interior Doors. All accessible first floor doorways shall provide a minimum clear opening of thirty-two (32) inches with the door open ninety (90°) degrees, measured between the face of the door and the opposite stop. 3. Switch And Outlet Requirements: All first floor wall switches controlling light fixtures and fans, shall be located at a height not to exceed forty-eight (48) inches above the finished floor. Height shall be determined by measuring from the finished floor to the center of the switch. All first floor receptacles shall be located at a height not less than fifteen (15) inches above the finished floor. Height shall be determined by measuring from the finished floor to the center of the switch. When the receptacle placement is prohibited by the height of a window or design feature, an alternate location can be approved by the chief building official or a duly authorized designee. 4. Washroom/Powder Room Design: Single-family and attached single-family dwellings shall include at least one (1) bathroom or powder room on the main level that provides a minimum thirty-two (32) inch clear path to the toilet, lavatory, and shower/tub (if present). This bathroom or powder room shall be designed and constructed in a manner that allows a person to use a wheelchair or mobility aid access to plumbing fixtures and the concurrent ability to close the door while inside. It is not essential to provide a full turning radius, although this would be preferred and encouraged. An outward-swinging door shall be permitted where space limitations exist, provided the hallway or adjacent space design allows the necessary clearances for safe egress. 5. Minimum Hallway Width: The minimum width of a hallway or path to an exit access shall not be less than forty-two (42) inches. A cased opening or drywalled opening that functions as a transition between rooms, between hallways, or a transition from one space to another and that provides at least a thirty-two (32) inch clear passage, shall be permitted within a hallway segment for purposes of compliance with this section. 6. When Required: To be consistent with existing Visitability requirements, compliance would be required in new construction. In the situation of an addition or remodeling, new construction would include additions which increases total square footage of a dwellings main level, and/or the addition of a main level washroom which did not R324.4.6 Glazing Adjacent to Stairs and Ramps: Revise Exception 2. Exception 2. Glazing 60 inches or more measured horizontally from the walking surface. Chapter 4 Foundations R401.4 Geotechnical Evaluation, Add R401.4.3 to read as follows: The allowable soil bearing pressure of a presumptive design soil bearing capacity of not more than 3,000 psf may be assumed in lieu of a complete geotechnical evaluation unless expansive soils, compressive soils, shifting soils, or other questionable soil characteristics are likely to be present. R402.1 Wood Foundations: Delete in its entirety, also delete all references to wood foundations throughout the code. R403.1.4.1 Frost Protection: Delete 3. R404.2 Wood foundation walls: Delete in its entirety, also delete all references to wood foundation walls throughout the code. Chapter 5 Floors R504 Pressure Preservative Treated-Wood Floors (on ground): Delete in its entirety. R507.3.1 Footings, Minimum Size: Change to read as follows: The minimum size of concrete footings shall be in accordance with Table R507.3.1 or other approved method, based on the tributary area and allowable soil bearing pressure of a presumptive design soil bearing capacity of not more than 3,000 psf. R507.9.2 Lateral Connection: Add new section as follows: The prescriptive hold-down lateral connection as identified in Section R507.9.2 shall not be required for decks 30" or less above grade. For decks 30" or less above grade, the lag screw/bolt connections from the deck ledger to band joist required by R507.9.1 shall be accepted. Chapter 6 Wall Construction R606.1.1 Professional Registration Not Required: Delete in its entirety Add a new section to read as follows: R703.9.3 Exterior Insulation Finish System (EIFS) If any exterior insulation finish system (EIFS) is installed on any portion of a dwelling unit for an exterior covering, a certification of proper installation shall be required to be submitted as a special inspection. Before permit issuance, a statement of special inspections prepared by the registered design professional, or certified contractor, shall be submitted detailing the individuals and approved agencies intended to be retained for conducting these inspections. This report and signed certification shall be submitted to the city before any occupancy will be granted. Chapter 8 Roof-Ceiling Construction Add a new section as follows: R802.11.1.3 Roof Tie-Down: Rafter ties shall be required on tray and cathedral ceilings or calculations must be submitted signed and sealed by the design professional for the wind uplift forces. Chapter 9 Roof Assemblies R903.5 Sloped Roofs: Gutters And Downspouts: All structures shall be provided with gutters and downspouts unless omission is specifically permitted by the building official. Chapter 24 Fuel Gas G2422.1 (IFGS 411.1) Connecting Appliances: Change first sentence to read: Furnaces, water heaters and boilers (unless specifically required by the manufacturer), shall be connected to the gas piping system by only rigid metallic pipe and fittings. Appliances, except furnaces, water heaters, and boilers (unless specifically required by the manufacturer), shall be connected to the piping system by one of the following: Chapters 25—32 Plumbing Requirements Add a new section as follows: P2501.1.1 All plumbing work shall conform to the current edition of the Illinois state plumbing code, the provisions of this code, and the current edition of the international plumbing code, adopted herein, whichever is more restrictive. Chapters 34—40 Electrical Requirements Add a new section as follows: E3401.1.1 All electrical work shall conform to the 2023 edition of the National Electrical Code and the ICC electrical code, both as adopted herein, and provisions of this code, whichever is more restrictive.
(Ord. No. 02-31, 2-19-2002, eff. 4-8-2002; Ord. No. 03-74, 3-4-2003; Ord. No. 04-229, 12-21-2004; Ord. No. 06-301, 12-19-2006, eff. 1-1-2007; Ord. No. 08-056, 3-18-2008; Ord. No. 12-159, § 1(Exh. A), 12-18-2012; Ord. No. 18-141, § 2, 12-4-2018; Ord. No. 21-066, § 2, 6-15-2021; Ord. No. 26-010, § 2, 2-17-2026)
Ask a question about Naperville law
Corpus searches the Naperville sections it holds and shows the ones that match, with their citations. Free, no sign-in.