§ 2A-17 — Establishment of heliports and helicopter landing sites and the uses of same

Code of Ordinances, Lexington-Fayette Urban County Government, Kentucky (Republication: codified through Ordinance No. 048-2025, adopted June 26, 2025 (online July 17, 2026)) · Lexington-Fayette Urban County Code of Ordinances § 2A-17

Corpus is an independent public-information project, not the official City of Lexington-Fayette urban county website. Stable reference: corpuslaw.us/code/bc7a9b0b-552a-4c38-97cd-3998d4f6ae06

Sec. 2A-17 - Establishment of heliports and helicopter landing sites and the uses of same.

Heliport: No site shall be used as a heliport unless and until the location and construction of same has been approved by the division of building inspection of the urban county government in consultation with the fire marshal and the police chief as meeting at least the following minimum specifications: A heliport must conform to all applicable zoning ordinance resolutions of the Lexington-Fayette Urban County Government. Every location approved or used as a heliport shall consist of a hard-surface or grassed area with good drainage and free of dust and gravel, not less in length and width or diameter than twice the length of any helicopter landing or taking off. Such area shall be set aside exclusively for such landing or taking off, be free of trees, wires and other obstructions, and be enclosed by a fence at least four (4) feet in height unless the entire area to be served by the heliport shall be enclosed by said fence or said heliport is located upon the roof of a building. Every heliport shall have at least two (2) approach paths free and clear of obstructions extending outward and upward from the landing and takeoff area at an angle of eight (8) feet horizontally to one (1) foot vertically, flaring to a width of five hundred (500) feet at an altitude of five hundred (500) feet. The center line of such paths or planes shall be separated by an arc of at least ninety (90) degrees. The remaining peripheral area surrounding the landing and takeoff area shall be free and clear of obstruction at an angle of two (2) feet horizontally to one (1) foot vertically to a lateral distance of two hundred fifty (250) feet from the landing and take off area. No approach path shall be used and no helicopter shall be flown at an elevation of less than five hundred (500) feet over a residence, building, school or public building, or closer than two hundred (200) feet to any building, structure or public highway, except for the purpose of landing or taking off. All fuel stored upon the heliport shall be stored in accordance with the applicable regulations of the urban county fire marshal and the state fire marshal's office. Every rooftop or platform heliport shall be constructed of noncombustible materials having a fire-resistance rating of not less than two (2) hours, supported by a building or structure of equivalent fire-resistance rating. Openings in the roof or platform shall not be permitted in the immediate landing area. At least two (2) approved means of egress, remote from each other, shall be provided from each rooftop landing area. Such means of egress shall be by enclosed stairways at least equal in fire-resistance rating to that required by the building code for the specific occupancy of the building. Fire extinguishers, building standpipe systems or other source of water supply and at least two (2) hose stations remote from each other, shall be provided subject to detailed specifications prescribed by the fire marshal. Every person intending to establish and use a heliport within the urban county shall first submit plans for approval to the division of building inspection of the urban county government, consisting of at least the following: A statement as to the intended use of the heliport, whether public or private, commercial or otherwise, the identity and financial responsibility of the management, frequency of flights, size, type and manufacture of equipment intended to be used, and hours of operation. A plan of the proposed site showing dimensions of the entire usable areas, dimensions of actual landing and takeoff areas, all obstructions within one thousand (1,000) feet of the heliport indicating their heights, and drawings of flight and approach paths within one thousand (1,000) feet of the heliport, and lighting, access and drainage plans. A report by a registered professional engineer showing that the roof structure or platform for any elevated heliport is designed to support concentrated loads on any one (1) square foot equivalent to three-fourths gross weight of the largest helicopter to be accommodated, assuming that the load is concentrated only at the point of contact under each main landing gear. Such other plans, documents or related additional information as may reasonably be requested by the division of building inspection. Helicopter Landing Site: No site shall be used as a helicopter landing site unless and until the location of same has been approved by the division of building inspection of the urban county government in conjunction with the urban county fire marshal and the chief of police or his designated representative as meeting at least the following minimum specifications: A helicopter landing site must conform to all applicable zoning ordinance resolutions of the Lexington-Fayette Urban County Government. Every location approved or used as a helicopter landing site shall consist of a ground level hard surfaced or grassed area of sufficient size to permit the safe operation of helicopters in taking off and landing. Such area shall be capable of being set aside exclusively for such landing or taking off; except parking lots or fields located adjacent to buildings located in business or industrial zones shall be permitted to be used as helicopter landing sites. No fueling, repairing or maintenance of helicopters shall be performed in such helicopter landing site except in case of emergency. Every person intending to establish and use a helicopter landing site shall submit plans for approval to the division of building inspection of the urban county government. Said plans shall contain at a minimum a plan of the proposed site, showing the dimensions of the actual landing and takeoff areas, and all obstructions within one thousand (1,000) feet of the helicopter landing site, indicating their height and relative location and lighting, access and drainage plans, together with such additional related information as may be reasonably requested by the division of building inspection. (Ord. No. 219-75, § 3, 8-7-75)

Ask a question about Lexington-Fayette urban county law

Corpus searches the Lexington-Fayette urban county sections it holds and shows the ones that match, with their citations. Free, no sign-in.