For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 51A-13.305 — BUILDING ELEMENTS

Dallas City Code (7/2026 Code (S-33): Vols. I-II current through Ordinance 33447, passed June 10, 2026; Vol. III through Ordinance 33484, passed June 24, 2026) · Dallas City Code § 51A-13.305

Corpus is an independent public-information project, not the official City of Dallas website. Stable reference: corpuslaw.us/code/54a8562b-00d7-43b1-ab46-d8542e1e1132

SEC. 51A-13.305. BUILDING ELEMENTS.

(a) Arcades. [image omitted; see the official code] (1) Arcades are permitted on mixed use shopfront, single-story shopfront, general commercial, and civic development types. (2) An arcade must have a clear depth from the support columns to the building’s facade of at least eight feet and a clear height above the sidewalk of at least 10 feet. (3) An arcade must be contiguous and extend over at least 50 percent of the width of the building facade. (4) No arcade may encroach into the door yard or the public right-of-way. (b) Galleries. [image omitted; see the official code] (1) Galleries are permitted on mixed use shopfront, single-story shopfront, general commercial, and civic development types. (2) A gallery must have a clear depth from the support columns to the building’s facade of at least eight feet and a clear height above the sidewalk of at least 10 feet. (3) A gallery must be contiguous and extend over at least 50 percent of the width of the building facade from which it projects. (4) A gallery may encroach into the door yard. No gallery may encroach into the public right-of-way without a license for the use of that right-of-way. (c) Awnings. [image omitted; see the official code] (1) Awnings are permitted on mixed use shopfront, single-story shopfront, general commercial, apartment, and civic development types. (2) A ground-story awning must have a minimum clearance of 10 feet above the sidewalk and must have a minimum depth of six feet. (3) An awning may encroach into the door yard. No awning may encroach into the public right-of-way without a license for the use of that right-of-way. (d) Balconies. [image omitted; see the official code] (1) Balconies are permitted only on the upper stories of mixed use shopfront, general commercial, apartment, townhouse stacked, townhouse, manor house, single- family house, and civic development types. (2) No balcony may project within five feet of a common lot line. (3) A balcony may encroach into the door yard. No balcony may encroach into the public right-of-way without a license for the use of that right-of-way. (e) Stoops. [image omitted; see the official code] (1) Stoops are permitted on townhouse stacked, townhouse, manor house, apartment, and single-family house development types. (2) A stoop must be no more than five feet deep (including the steps) and six feet wide. (3) A stoop may be roofed, but not enclosed. (4) Partial walls and railings on a stoop may be no higher than 3 1/2 feet. (5) A stoop may encroach into the door yard. No stoop may encroach into the public right-of-way without a license for the use of that right-of-way. (f) Front Porches. [image omitted; see the official code] (1) Front porches are permitted on townhouse stacked, townhouse, manor house, apartment, and single-family house development types. (2) A front porch must be a minimum of six feet deep (not including the steps). (3) Except as provided in this paragraph, a front porch must be contiguous with a width not less than 50 percent of the building facade from which it projects. This provision does not apply to the apartment development type. (4) A front porch may be roofed, but not enclosed. (5) Partial walls and railings on a porch may be no higher than 3 1/2 feet. (6) A front porch may encroach into the door yard. No front porch may encroach into the public right-of-way without a license for the use of that right-of-way. (g) Roof Treatments. Dormers are permitted in an attic story. Dormers must not break the primary eave line, be individually more than 15 feet wide, and collectively be more than 60 percent of the facade length. (h) Building Entrances. (1) The following building entrance requirements apply to mixed use shopfront, single-story shopfront, general commercial, and apartment development types. (2) An entrance providing both ingress and egress, operable during normal business hours, is required to meet primary street entrance requirements. Additional entrances off another street, pedestrian area, or internal parking area are permitted. (3) The entrance separation requirements provided for the development type must be met for each building, but are not applicable to adjacent buildings. (4) An angled entrance may be provided at either corner of a building along the primary street to meet the primary street entrance requirements, provided any applicable entrance spacing requirements can still be met. (5) A minimum of 50 percent of a required entrance must be transparent. (6) A required fire exit door with no transparency may front on a primary, side, or service street. (i) Fences and Walls. (1) Except as provided below, the provisions of Section 51A-4.602 apply. (2) In a door yard, a fence may not exceed three feet in height above grade. In all other required yards, no fence or wall may exceed six feet in height above grade. (Ord. 30889)

Ask a question about Dallas law

Corpus searches the Dallas sections it holds and shows the ones that match, with their citations. Free, no sign-in.