§ 9-21 — Amendments to the International Plumbing Code
Code of the City of Glendale, Arizona (Supp. No. 115: codified through Ordinance No. O26-19, adopted April 14, 2026) · Glendale City Code § 9-21
Corpus is an independent public-information project, not the official City of Glendale website. Stable reference: corpuslaw.us/code/002cffe9-9ddf-442d-adf5-7b601eee88aa
Sec. 9-21. - Amendments to the International Plumbing Code.
Section 101.1 Title is amended to read as follows: These regulations shall be known as the Plumbing Code of the City of Glendale, Arizona hereinafter referred to as "this code." Chapter 1 is amended by the deletion of Sections R102 through R115. For the administration of this code, see the 2024 International Building Code and related amendments. Section 301.6 Prohibited Locations, Exception is amended to read as follows: Exception: Floor drains, sumps and sump pumps shall be permitted at the base of the elevator shaft, provided they are daylighted to landscape or indirectly connected to the plumbing system and comply with Section 1003.4. Section 305.4.1 Sewer Depth is amended as follows: Building sewers that connect to private sewage disposal systems shall be installed not less than 12 inches below finished grade at the point of septic tank connection. Building sewers shall be installed not less than 12 inches below grade. Section 410.4 Substitution is amended by revising the last sentence to read: In other occupancies where drinking fountains are required, water dispensers shall be permitted to be substituted for drinking fountains. Section 412, Faucets and Fixture Fittings, add the following subsection: 412.13 Automatic faucets. New or replacement faucets serving lavatories in all buildings other than R3 occupancies, individual units in R2 occupancies, or International Residential Code structures shall be provided with automatic faucets in accordance with Table 604.4. Section 604.4, delete and replace with the following: Section 604.4 Maximum flow and water consumption. The maximum water consumption flow rates and quantities for all plumbing fixtures and fixture fittings shall be in accordance with Table 604.4. Exception: Replacement of existing fixtures that do not require a permit. TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FITTINGS Plumbing Fixture or Fixture Fitting | Maximum Flow Rate or Quantity b Lavatory, private | 1.5 gpm at 60 psi Lavatory, public | 0.25 gallon per metering cycle Lavatory, public (other than metering) | 0.5 gpm at 60 psi Shower heads a,c | 2.0 gpm at 80 psi Sink faucet | 1.8 gpm at 60 psi Flushing urinals | 0.5 gallons per flush Water closet | 1.28 gallons per flush d,e For SI: 1 gallon = 3.785 L, 1 gallon per minute = 3.785 L/m, 1 pound per square inch = 6.895 kPa a A hand-held shower spray is a shower head. b Consumption tolerances shall be determined from referenced standards. c Shower heads shall comply with all requirements for high-efficiency shower heads in ASME A112.18.1-2020/CSA B125.1 d For a dual-flush water closet, the full-flush volume shall not exceed 1.28 gallons. e A 1.6 gallon per flushing cycle is permitted where a water closet is connected to a building's existing sanitary drainage piping. Section 605.2, Lead Content of Water Supply Pipe and Fittings is amended to read as follows: The lead content in pipe and fittings used in the water supply system shall comply with 40 CFR 143.12(a) as "lead free" as follows: 1. Not contain more than 0.2 percent lead when used with respect to solder and flux; and, 2. Not have more than a weighted average of 0.25 percent lead when used with respect to the wetted surfaces of pipes, pipe fittings, plumbing fittings and fixtures. Chapter 7 is amended as follows: Any reference in this chapter that refers to the International Private Sewage Disposal Code shall be deferred to the Maricopa County Environmental Services Department. Section 701.5 Damage to drainage system or public sewer is amended to reference Section 1003 in its entirety and any requirements in that section shall be deferred to the City of Glendale Water Services Department. Section 803 Special Wastes is hereby amended to defer to the City of Glendale Water Services Department. Section 903.1.1 Roof Extension is amended as follows: This section allows the Authority Having Jurisdiction to determine the minimum height above a roof that a vent must terminate. The City of Glendale shall require that all vents terminate a minimum of 6 inches above the roof and not less than 12 inches from any vertical surface. Section 1003 Interceptors and Separators is amended by deferring to the requirements of the City of Glendale Water Services Department where applicable. Chapter 13 Non-Potable Water Systems is amended by deleting this chapter in its entirety. These systems shall be designed and constructed in accordance with applicable Maricopa County and State of Arizona regulations and requirements.
(Ord. No. O25-51, § 1, 12-9-25)
Ask a question about Glendale law
Corpus searches the Glendale sections it holds and shows the ones that match, with their citations. Free, no sign-in.
