§ 18.49.060 — Amend CEBC Section 805.3—Existing structural elements resisting lateral loads

Long Beach Municipal Code (Supp. No. 53, Update 1: codified through Ordinance No. ORD-26-0027, enacted October 13, 2026) · Long Beach Municipal Code § 18.49.060

Corpus is an independent public-information project, not the official City of Long Beach website. Stable reference: corpuslaw.us/code/00993ce9-f632-476c-9e67-ea2ba572eb39

18.49.060 - Amend CEBC Section 805.3—Existing structural elements resisting lateral loads.

Section 805.3 of the California Existing Building Code is amended to read as follows: 805.3 Existing structural elements resisting lateral loads. Except as permitted by Section 805.4, where the alteration increases design lateral loads, or where the alteration results in prohibited structural irregularity as defined in ASCE 7, or where the alteration decreases the capacity of any existing lateral load-carrying structural element, the lateral force-resisting system of the altered building or structure shall meet the requirements of Section 1609 of the California Building Code and Section 304.3.2 of this code. Alternative procedures to demonstrate compliance with Section 1609 of the California Building Code and Section 304.3.2 of this code, as determined by the Building Official, may be used. Where the lateral force-resisting system consists of unreinforced masonry, refer to Chapter 18.68 of the Long Beach Municipal Code. Exceptions: 1. Any existing lateral load-carrying structural element whose demand-capacity ratio with the alteration considered is not more than 10 percent greater than its demand-capacity ratio with the alteration ignored shall be permitted to remain unaltered. For purposes of calculating demand-capacity ratios, the demand shall consider applicable load combinations with design lateral loads or forces in accordance with Section 1609 of the International Building Code and Section 304.3.1 or 304.3.2 of this code. The same methodology shall be used for the altered and unaltered structures. For purposes of this exception, comparisons of demand-capacity ratios and calculation of design lateral loads, forces and capacities shall account for the cumulative effects of additions and alterations since original construction. When calculating demand-capacity ratios for wind, the date of original construction shall be permitted to be taken as the date of completion of a prior addition, alteration or repair in compliance with Section 1609 of the California Building Code or the code wind forces in effect at the time. When calculating demand-capacity ratios for earthquake, the date of original construction shall be permitted to be taken as the date of completion of a prior addition, alteration or repair in compliance with Section 304.3.1 or 304.3.2 Item 1 or 3 or the full or reduced seismic forces in effect at the time. 2. Buildings in which the increase in the demand-capacity ratio is due entirely to the addition of rooftop-supported mechanical equipment individually having an operating weight less than 400 pounds (181.4 kg) and where the total additional weight of all rooftop equipment placed after initial construction of the building is less than 10 percent of the roof dead load. For purposes of this exception, "roof" shall mean the roof level above a particular story. 3. Increases in the demand-capacity ratio due to lateral loads from seismic forces need not be evaluated for the installation of rooftop photovoltaic panel systems where the additional roof dead load due to the system, including ballast where applicable, does not exceed 5 pounds per square foot (psf) (0.2394 kN/m 2 ) and does not exceed 10 percent of the dead load of the existing roof.

(ORD-25-0019 § 1(Exh. A), 2025)

Ask a question about Long Beach law

Corpus searches the Long Beach sections it holds and shows the ones that match, with their citations. Free, no sign-in.