30-0304. - Oil burner installation.

The construction, arrangement and manner of installation of all oil burners and oil-burning equipment hereafter installed for use in connection with heating plants in or for buildings in the city, and the alteration or repair hereafter of such installations shall conform to the following provisions: A. Exception. This chapter does not apply to oil heaters and oil lamps equipped with a wick or a mechanical device, the movement of which is essential to flame adjustment, or to such portable apparatus as blowtorches, soldering pots, etc., but does include all types, classes, and sizes of oil-burning water heaters and space heaters, regardless of their oil container or tank capacity. B. Approved oil burners required. It shall be unlawful for any person to install within the city any oil burner not approved by the Underwriters Laboratories or other nationally recognized testing laboratory. C. Inspection. The building inspector shall automatically approve any oil burners listed by the Underwriters Laboratory or any other nationally recognized inspection board or laboratory. Oil burners not listed by the Underwriters Laboratory or any other nationally recognized board or laboratory shall not be approved. D. Oil-heating equipment—Installation permit. Any qualified person may install approved oil-burning equipment in connection with an approved oil burner in accordance with the provisions of this chapter but no oil-burning equipment shall be installed in the city unless and until the building inspector shall have issued a permit for the specific installation. E. Definition of permit. A permit is the written authority of the building inspector issued pursuant to this charter for the installation of an oil burner and its associated equipment covered by this chapter or any material entering into the composition thereof. F. Application for installation permit. Application for an installation permit shall be made in writing signed by the dealer or installer stating the location of the property in which the installation is intended, the name, type and model of the burner, type and model of controls, and the number and capacity of tanks for storage of fuel, accompanied by a sketch, if deemed necessary by the building inspector, showing the layout of the proposed installation. G. Granting permits. Within 48 hours after filing of an application and sketch in accordance with this chapter, the building inspector shall issue such permit or in writing notify the applicant of changes required before a permit will be issued or the reasons why the application is denied. Upon the required changes being made in the application or sketch, a permit shall be issued. No oil burner or equipment of a different kind than that specified in the application and no tanks of different sizes, kind, or quality shall be installed, nor shall the installation be made in any manner other than as described in such application or shown in the sketch submitted therewith. H. Inspection of installation. All installations of oil burners or equipment within the city shall be inspected by the building inspector. An approval of installation shall be given the installer before any oil burner is turned on for use. The installer shall give at least eight hours' notice that the installation is ready for inspection. I. Installation of used oil Burners—Procedure to be required. No person shall install a used oil burner or use in connection with a heating plant until he shall have furnished the building inspector with a statement that said oil burner has been put in first-class operating condition and with a letter from the purchaser acknowledging that said purchaser is buying a used oil burner. J. Fuel oil. The grade of fuel oil used with any oil burner shall be one which tests and experience have shown to be suitable for use with that burner. The oil shall have a flash point not less than 100° Fahrenheit, determined as specified in paragraph (B) of § 30-0301 of this article, and shall be free from acid, grit, and fibrous or other foreign matter likely to clog or injure the burner or valves. K. Commercial standard. The commercial standards (Grades 1, 2, 3, 5, and 6) for domestic and industrial fuel oils, set up by the U.S. Department of Commerce, Bureau of Standards Bulletin CS 12-40 (effective June 5, 1940) shall constitute standard grades for fuel oil sold or delivered to oil burners within the city, and it is hereby declared a violation of this chapter for any person to deliver for use as fuel in an oil burner or burners, or put into the storage tank of any oil burner or burners a grade of oil heavier than that which has been approved by the building inspector for use in such burner or burners. L. Secondary controls—Thermostats. All domestic types of oil-burner installations in the city shall be equipped with a modern type of thermostat for the secondary control of the oil burner. M. Electrical installations. Electrical installations used in connection with oil-burning equipment shall be installed in accordance with the electrical code of the city. N. Combustion chamber dimensions. It shall be unlawful for any person to install any oil burner into a combustion chamber if the chamber is of a design, size, or type other than that which has been specified by the manufacturer as being the correct design, size, or type for the size of nozzle and angle of atomization with which the oil burner being installed is equipped. 0. Flue gas analysis tests. Before any final approval shall be given by the building inspector on any installation of any type of oil burner covered by the provisions of this chapter, the person installing the same shall make a test, or tests, commonly known as a flue gas analysis test in the presence of the inspecting officer if deemed necessary by the building inspector. The findings of such analysis shall be recorded upon the inspection approval form.

Source: 1952 Rev. Ord. 968 (1956), 1087 (1960).

Ask a question about Fargo law

Corpus searches the Fargo sections it holds and shows the ones that match, with their citations. Free, no sign-in.