For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 82-396 — Windows

Code of the City of New Orleans (Supp. No. 118, Update 1: codified through Ordinance No. 30771, adopted September 17, 2026) · New Orleans City Code § 82-396

Corpus is an independent public-information project, not the official City of New Orleans website. Stable reference: corpuslaw.us/code/0161fb55-1769-4593-9a8b-09a0a972f698

Sec. 82-396. - Windows.

(a) All windows and other openings for the purpose of light and ventilation located in the side or rear of exterior walls and within 30 inches above the existing ground level immediately below such openings shall be covered for their entire height and width, including frame, with wire cloth of 19 gauge or heavier, having a mesh of not larger than one-half inch. (b) All windows and other openings for the purpose of light or ventilation in the exterior walls that may be accessible to rats by way of exposed pipes, wires, conduits or other appurtenances shall be covered with guards of wire cloth of 19 gauge or heavier, having a mesh of not larger than one-half inch or, in lieu of wire cloth covering, such pipes, wires, conduits and other appurtenances shall be blocked from rat usage by installing sheet metal guards of 24 gauge or heavier. Such guards when used on horizontal pipes, wires, conduits or other appurtenances shall be placed in a vertical position and shall be fitted snugly around the pipe, wire, conduit or other appurtenances. Any such guard shall measure not less than 12 inches beyond and on all sides of the pipe, wire, conduit or other appurtenance where the intervening space between the wall and the pipe permits and shall extend 30 inches in an upward direction and 12 inches in a downward direction and shall be securely fastened to the pipe, wire, conduit or other appurtenance and also to the adjacent wall wherever practicable so that the guard will remain in a vertical position at all times. (c) Such guards when used on vertical pipes, wires, conduits or other appurtenances shall be fitted snugly around the pipe, wire, conduit or other appurtenance, shall be placed in a horizontal position (right angle to pipe, etc.) and shall extend horizontally from the pipe, wire, conduit or other appurtenance for a minimum distance of 12 inches beyond and on all sides of the pipe, wire, conduit or other appurtenance where the intervening space between pipe and wall permits and shall be securely fastened to the pipe, wire, conduit or other appurtenance and also to the adjacent wall wherever practicable in such a manner that the guard will remain in a horizontal position at all times.

(Code 1956, § 54-11)

Ask a question about New Orleans law

Corpus searches the New Orleans sections it holds and shows the ones that match, with their citations. Free, no sign-in.