For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 21-709 — Permanent Sign Types

Peoria, Arizona, City Code (2026 S-10: Local legislation current through Ord. 2026-20, passed 10-6-26) · Peoria, Ariz., City Code § 21-709

Corpus is an independent public-information project, not the official City of Peoria website. Stable reference: corpuslaw.us/code/01a049fb-96ce-4b7a-accb-61281538aec3

Sec. 21-709. Permanent Sign Types.

General standards: A. Authorized Signs. Authorized Permanent Signs are noted on the following pages, and comprise of the following Tables: Table 1: Building Sign Specifications Table 2: Freestanding Sign Specifications Table 3: Other Sign Type Specifications B. Accessory Use. All permanent signs are considered ancillary, or accessory, uses. As such, a principal use must be legally established and developed on a property in order for a permanent sign to be allowed on the property. C. Changeable Copy. Electronic message centers may be utilized for permanent signs where changeable copy is permitted. D. Design and Integration. All permanent signs shall be fully integrated with the design of the building and the site development, reflecting the architecture, building materials and landscape elements of the project. 1. The means of integrating freestanding monument signs within the architecture of the building shall be achieved through replication of architectural embellishments, colors, building materials, texture and other elements exhibited in the building design. 2. In no case shall any sign be secured with wires such as guy wires or strips of wood which are visible and not an integral part of the sign. 3. Signs shall be designed in coordination with landscape plans, planting materials, storm water retention requirements, and utility pedestals, so as not to create problems with sign visibility or prompt the removal of required landscape materials. E. Illumination: 1. In residential zoning districts, illuminated signs for permitted non-residential uses within two hundred (200) feet of residential uses or undeveloped residentially zoned property, whether directly adjacent or across a road, shall go dark between the hours of 10 p.m. and 5 a.m. or when the establishment is closed, unless otherwise permitted within this Section. 2. All signs with exposed LED illumination shall be limited to a brightness of 0.3 foot candles above ambient lighting. All other internally illuminated signs shall be limited to a brightness of 0.6 foot candles above ambient lighting. 3. Signs allowed to be illuminated may utilize internal illumination (direct or backlit) or external illumination, unless otherwise specified in Tables 1 and 2. 4. External illumination shall be compliant with Dark Sky light control requirements, including the requirements in Chapter 20 of the Peoria City Code. 5. Within the Downtown/Commercial Mixed Use (D/CM) sub-zoning district, all signage with neon: i. Must be equipped with automatic dimming technology that automatically adjusts the sign's brightness in direct correlation with ambient light conditions. ii. Where neon signs directly face properties in a sub-zoning D/RM sub-zoning district or a single-family residential use, whether directly adjacent or across a road, the sign must be equipped with a sensor or other device that automatically adjusts the brightness of the lighting to comply the limitation of 0.3 foot candles above ambient light between the hours of 11:00 p.m. and 5:00 a.m., or when the establishment is closed, whichever is more restrictive. iii. Must have a smooth transition in the lighting level at a constant rate between daylight to nighttime brightness. iv. At no time shall lighting on a neon sign blink, flash or flutter. F. Landscaping. All permanent freestanding signs shall be located with the base of the sign in a landscape area. This landscape area shall be equal to a minimum of 4 square feet for each square foot of sign area. G. Location. All design and structural components of a freestanding sign (e.g. the footer, base, etc.) shall be setback a minimum of one (1) foot from the edge of the street right-of-way. H. Monument Sign Base Material. All permanent freestanding signs greater than three (3) feet in height shall have a masonry base (e.g. brick, CMU, stone) that is consistent with the site's architectural/thematic design. I. Standard Abbreviations. Standard abbreviations used within the tables are identified below: Standard Abbreviations Adj. - Adjacent | FT - Feet or foot IN - Inches | LF - Linear Feet or Linear Foot N/A - Not applicable or not allowed | SF - Square feet or square foot SVT - Sight visibility triangle | ROW - Right-of-Way Rd. - Road | Pkwy. - Parkway Min - Minimum | Max - Maximum > - Greater Than | > Greater Than or Equal To < - Less than | < Less than or equal to Table 1: Building Sign Specifications A. ADDRESS SIGN | Permit: No [image omitted; see the official code] | Description | Numerals that identify the street address of a property for public safety purposes. Residential Uses & Non-Residential Uses | Permitted in compliance with Building and Fire Code requirements. Notes: None B. AWNING AND ATTACHED CANOPY SIGN | Permit: Yes [image omitted; see the official code] | Description: | A sign which is printed, painted, or affixed to an awning or canopy which is attached to a building. Residential Uses | Total Sign Area Allowed | N/A Non-Residential Uses | Max Quantity | N/A | Max Height | 1st Floor awnings only # | Illumination Allowed | Internal, backlit, external | Max Sign Area Allowed | 2 SF per 1 LF of an awning † Notes: # Signs may be mounted on or extend above attached canopy as long as they do not extend above the roof line. † Sign allowance is in addition to the total area permitted for all Wall Signs. C. BLADE AND HANGING SIGNS | Permit: Yes [image omitted; see the official code] | Description | A pedestrian-oriented sign that is attached to and supported by a building or other structure.(See Blade Sign and Hanging Sign Definition) Residential Uses | N/A Non-Residential Uses | Min Height | 8 FT above adjacent sidewalks and/or ground level | Min Projection | 14 IN from Building | Max Projection # | 3 FT from wall or less than awning/ canopy depth if attached | Illumination Allowed | Externally illuminated and backlit only | Max Sign Area Allowed | 12 SF † Notes:# Maximum projection is based on attachment type.† Sign allowance is in addition to total area permitted for all Wall Signs D. BUILDING WALL SIGN (e.g. Band Signs) | Permit: Yes [image omitted; see the official code] | Description | A permanent sign attached to, painted on, or otherwise assembled against the wall or fascia of a building with the exposed face of the sign parallel to the face of the wall or fascia. Residential uses | N/A Non- Residential Uses | Max Quantity | N/A | Max Projection | 14 IN | Illumination Allowed | Internal, backlit, external | Max Sign Area Allowed (Per Sign) | Based on Business Frontage † Ratio is 2 SF per 1 LF, up to Max If Business Frontage LF is: <20,000 SF = 125 SF Max 20,000-50,000 = 250 SF Max >50,000 SF = 400 SF Max Notes: † Sign allowance included in the total area permitted for all Wall Signs. E. ENTRY SIGN | Permit: No [image omitted; see the official code] | Description | A sign located adjacent to an entry door. Residential Uses & Non-Residential Uses | Max Quantity | 1 per dwelling unit or 1 per business | Max Height | 15 FT from door threshold | Max Projection | 4 IN | Illumination Allowed | External or backlit illumination only | Max Sign Area Allowed | 2 SF per sign Notes: None F. FREE STANDING CANOPY SIGN | Permit: Yes [image omitted; see the official code] | Description | Signs on freestanding canopies, such as fuel canopies, and shade structures. Residential Uses | N/A Non-Residential Uses | Max Quantity | N/A | Illumination Allowed | Internal, backlit, external | Max Sign Area Allowed | 12 SF per side Notes: None G. PROJECTING SIGN Permit: Yes [image omitted; see the official code] | Description | A pedestrian-oriented sign that is attached to and supported by a building or other structure. (See Projecting Sign in Section 21-705 Definitions) Residential Uses | N/A Non-Residential Uses | Min Height | 8 FT above adjacent sidewalks and/or ground level | Max Projection # | None † | Illumination Allowed | Internal, Externally illuminated, and backlit. Δ | Max Sign Area Allowed ∙ | Outside Downtown (D) District = 12 SF | | In D/CM facing D/RM or single-family residential use = 16 SF | | In D/CM not facing D/RM or single-family residential use = 36 SF Notes:∙ Sign allowance included in total area permitted for all Wall Signs.† Projection signs shall not extend past the property line, unless within the Downtown (D) District when approved as part of a license agreement.Δ Neon in D/CM is allowed subject to provisions of Section 21-709.E. Table 2: Freestanding Sign Specifications Sign Type Option Residential Uses Single-Family | N/A Multi-Family | Either Primary Monument Sign OR Perimeter Wall Sign. Non-Residential Uses* | Allowed either Primary/Secondary Monument(s) OR Perimeter Wall Sign. A. FREEWAY SIGN | Permit: Yes [image omitted; see the official code] | Description | A freestanding monument sign located on property adjacent to a freeway (See Freeway Sign in Section 21-705 Definitions) # Residential uses | N/A Non-Residential Uses | Max Quantity (Based on Freeway Frontage) | ≥660 LF = 1 | >1,320 LF = 2 | >2,640 LF = 3 | Illumination Allowed | Internal, backlit, external | Max Height | 60 FT + 3 FT for architectural detail | Max Sign Area Allowed | 250 SF Notes: # Sign must be located along the qualifying freeway frontage. Signs are only permitted for non-residential zoned properties. Base of sign must be at least 35% of the full sign width. Minimum Separation: 200 feet separation from other Freeway Signs, 50 feet from non-freeway lot lines, and 200 feet from residentially zoned property. B.1 PRIMARY MONUMENT SIGN (Residential Uses) | Permit: Yes [image omitted; see the official code] | Description | A freestanding monument sign adjacent to a residential development (See Freestanding Sign). Residential uses Single-family | N/A Multi-family # | Max Quantity | 1 per street frontage | Max Height | A designated pkwy., Bell Rd. & Grand Ave 12 FT | | Other Major Arterials 10 FT | | All Other Roads 8 FT | Max Sign Area Allowed | 48 sf. Notes # Only allowed either Primary Monument(s) or Perimeter Wall Sign. B.2 PRIMARY MONUMENT SIGN (Non-Residential Uses) | Permit: Yes [image omitted; see the official code] | Description | A freestanding monument sign within Large Centers (See Freestanding Sign and Large Center). Non-Residential Uses * Standards are based on the entire center or campus where applicable # | Max Quantity † (Based on length of street frontage) | 0 - 599 LF = 1 | | 600 LF - 1,000 LF = 2 | | > 1,000 LF = 3 | | LF calculated separately for each street where property has frontage | Max Height | A designated pkwy, Bell Rd. & Grand Ave. 16 FT | | Other Major Arterials 12 FT | | All Other Roads 8 FT | Max Sign Area Allowed∙ | A designated pkwy., Bell Rd. & Grand Ave. 72 SF | | Other Major Arterials 60 SF | | All Other Roads 48 SF Notes † Sign must be located along the qualifying street frontage. # Only allowed either Primary Monument(s) OR Perimeter Wall sign. ∙All Primary Monument Signs shall be located a minimum of 60 FT away from all other Primary and Secondary Monument signs. C. SECONDARY MONUMENT SIGN | Permit: Yes [image omitted; see the official code] | Description | A freestanding monument sign for a Small Center or at secondary entrances of a Large Center (See Freestanding Sign and Large Center). Residential uses | N/A Non-Residential Uses Standards are based on the entire center or campus where applicable | Max Quantity (Based on amount of street frontage) | 0 LF - 599 LF = 1 | | > 1,000 LF = 1 for every 300 LF | | LF calculated separately for each street where property has frontage | Max Height | Designated Pkwy 12 FT | | Major Arterials 8 FT | | All Other Roads 6 FT | Max Sign Area∙ | A designated pkwy., Bell Rd. & Grand Ave. 48 SF | | Other Major Arterials 32 SF | | All Other Roads 24 SF Notes: ∙ All Secondary Monument Signs shall be located a minimum of 60 FT away from all other Primary and Secondary Monument signs located in the same center or parcel. D. INTERNAL CENTER SIGN | Permit: No [image omitted; see the official code] | Description | Internal freestanding signage within a non- residential center. Residential uses | N/A Non-Residential Uses Standards are based on the entire center or campus where applicable | Max Quantity | 1 sign per parcel, or 1 sign per acre, whichever is greater. Individual parceled pads within a center are eligible for internal center signs. | Max Height | 3 FT | Max Sign Area Allowed | 6 SF Notes: Must be located internal to a site, outside of all street frontage landscape areas and buffers. E. PERIMETER WALL/SCREEN WALL SIGNS | Permit: Yes [image omitted; see the official code] | Description | A sign consisting of individually mounted characters on a perimeter or screen wall surrounding a development. Residential Uses Single-Family Developments (2 or more lots) and Multi-Family Developments | Max Quantity | 2 per street frontage providing direct access to development. | Max Height | 8 FT or wall height, whichever is less. | Max Projection | 14 IN | Illumination Allowed | External or backlit illumination only | Max Sign Area Allowed | 32 SF per sign Non-Residential Uses* | Max Quantity | 1 per street frontage | Illumination Allowed | External or backlit illumination only | Max Sign Area Allowed | 48 SF per sign or <50% of wall area, whichever is less. Notes: * Only allowed either Primary Monument, Secondary Monument(s) OR Perimeter Wall sign. Table 3: Other Sign Type Specifications A. DRIVE-THROUGH SIGN | Permit: Yes [image omitted; see the official code] | Description | Signage for uses with a drive-through. # Residential uses | N/A Non-Residential Uses | Max Quantity | 2 signs per drive-through lane | Max Height | 6 FT | Max Sign Area Allowed | 36 SF per sign Notes:# Must be located adjacent to drive-through lanes. Changeable copy is permitted. B. GAS STATION MONUMENT SIGN | Permit: Yes [image omitted; see the official code] | Description | Monument sign for a property containing a gas station/fuel service station. # Residential uses | N/A Non-Residential uses | Max Height | 8 FT | Max Sign Area Allowed | 32 SF, including 16 SF changeable copy Notes: # In accordance with Arizona Administrative Code, gas station monument signs shall be permitted in lieu of a primary or secondary monument for stand-alone gas stations, maximum 1 per frontage. Commercial centers containing gas stations shall be allowed Gas Station Monuments in addition to Primary and Secondary Monuments. C. FLAGS | Permit: No* [image omitted; see the official code] | Description | See Definitions. Residential uses | Max Quantity | 3 Flags, 1 pole Max Height #* | 30 FT Max Sign Area Allowed | 24 SF per flag Non-Residential uses | Max Quantity | 1 flag per 25 LF street frontage, up to 6 total per premises | Max Height #* | 50 FT | Max Sign Area Allowed | 36 SF Notes:# Flags must meet minimum principal building setbacks and shall not be located in any required utility easements.* Depending on the height, a building permit may be required. D. WINDOW SIGN | Permit: No [image omitted; see the official code] | Description | Signs placed on or within 3 FT of windows so as to attract the attention of persons outside of the building where the sign is placed. Residential uses | Limitations | No limit, non- commercial messages only Non-Residential Uses # | Max Sign Area Allowed* | 25% of the total window area on any one side of a building. | Illumination Allowed | Max of 2 signs may be internally illuminated, up to 2 SF per sign Notes:# Window signage is prohibited above the ground floor of the building.* When window signage is displayed on two or more sides of a building, each side shall comply with the maximum sign area provisions. (Ord. No. 2025-01, § 2(Exh. A), 1-14-25; Ord. No. 2026-06, § 3(Exh. A), 3-3-26)

Ask a question about Peoria law

Corpus searches the Peoria sections it holds and shows the ones that match, with their citations. Free, no sign-in.