For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 18.68.090 — DEVELOPMENT STANDARDS AND CRITERIA

City Code of Salt Lake City, Utah (2026 S-21: current through Ord. 49-26, passed September 15, 2026) · Salt Lake City Code § 18.68.090

Corpus is an independent public-information project, not the official City of Salt Lake City website. Stable reference: corpuslaw.us/code/0205021d-5ab8-49eb-86fb-06a55367ed55

18.68.090: DEVELOPMENT STANDARDS AND CRITERIA:

No final subdivision plat shall be approved nor shall any site development or building permit be issued for property located within the floodplain hazard area until the proposed development, construction, substantial improvement, or work under permit complies with the following criteria: A. All proposals for new construction or substantial improvements to existing structures within the floodplain hazard area (including manufactured homes and temporary structures or relocatable office buildings) must be designed or modified and anchored to prevent flotation, collapse or lateral movement of the structure resulting from hydrodynamic and hydrostatic loads including the effects of buoyancy and shall be constructed with materials and utility equipment resistant to flood damage. B. All proposals for development, construction or substantial improvements (including replacements) must be provided with water supply systems or sanitary sewage systems which are designed to minimize or eliminate infiltration of floodwaters into the system and discharges from the system into floodwater. On site waste disposal systems must be located so as to avoid impairment of, or contamination from, them during flooding. All public utilities, including sewer, gas, electricity and water systems and other service facilities shall be designed, located and/or constructed to prevent water from entering or accumulating within the components during conditions of flooding. All public improvements (including, but not limited to, streets, sidewalks, curbs, and gutter), shall be designed and constructed with adequate drainage systems to minimize the containment of floodwaters on adjacent properties. C. Building or structures and development activities shall be designed and completed on the site so as to offer minimum obstruction to the flood or floodwaters. Whenever floodwaters could be four feet (4') or more in depth and have a velocity of two feet (2') per second or greater on a site, as determined by the city floodplain administrator, buildings or structures shall be constructed and development activities shall be designed with the longitudinal axis parallel to the direction of the flood flow. So far as is practicable, buildings or structures shall be placed approximately on the same flood flow lines as those of adjoining structures. D. No buildings, structures or earth fill shall be constructed or developed that will: 1. Cause an increase of more than one foot (1') in the probable water surface elevation in any floodplain hazard area; or 2. Result in storage or processing of flammable, explosive or dangerous materials within the floodplain hazard area. E. No buildings, structures, substantial improvements, earth fill or other encroachments shall be constructed or developed within the regulatory floodway. F. If a structure has been floodproofed, the elevation of such floodproofing (in relation to mean sea level) must be certified by a registered professional engineer or registered land surveyor and must also be submitted to the building official. G. Adequate drainage paths shall be provided around structures located on slopes within any AO or AH zone to guide floodwater around and away from proposed structures. H. Fully enclosed areas in buildings, structures, and substantial improvements below the lowest floor that are subject to flooding shall be designated to automatically equalize hydrostatic flood forces on exterior walls by allowing for the entry and exit of floodwaters. Designs for meeting this requirement must either be certified by a registered professional engineer or architect or must meet or exceed the following minimum criteria: A minimum of two (2) openings having a total net area of not less than one square inch for every square foot of enclosed area subject to flooding shall be provided. The bottom of all openings shall be no higher than one foot (1') above grade. Openings may be equipped with screens, louvers, or other coverings or devices provided that they permit the automatic entry and exit of floodwaters. (Ord. 50-09 § 1, 2009)

Ask a question about Salt Lake City law

Corpus searches the Salt Lake City sections it holds and shows the ones that match, with their citations. Free, no sign-in.