§ 1607 — Live Loads
Baltimore City Code (current through Ord. 26-129 (July 17, 2026); publication of Oct. 18, 2026) · Baltimore City Code, Building Codes, Part II, Section 1607
Corpus is an independent public-information project, not the official City of Baltimore website. Stable reference: corpuslaw.us/code/0224b1d5-fdd1-4c56-b40e-a6f5ba180bf5
Section 1607. Live Loads
1607. 1607.1 to 1607.13 {As in IBC} 1607.14 Roof Loads. {As in IBC} 1607.14.1 Distribution of roof loads. {As in IBC} 1607.14.2 Reduction in roof live loads. {As in IBC} 1607.14.2.1 Ordinary roofs, awnings, and canopies. Ordinary flat, pitched, and curved roofs, and awnings and canopies other than opf fabric construction supported by a skeleton structure, must be designed for the following minimum live loads: Roof Slope | Live Load (pounds/square foot of horizontal projection) Flat: | Flat or rise less than 4" | 30 Pitched: | Rise 4" (102 mm) per foot to less than 12" (305 mm) per foot | 20 Rise 12" (305 mm) per foot and greater | 12 Curved: | Arch or dome with rise less than 1/8 of span | 30 Arch or dome with rise 1/8 of span to less than 3/8 of span | 20 Arch or dome with rise 3/8 of span or greater | 12 1607.14.2.2 to 1607.14.4.5 {As in IBC} 1607.15 to 1607.22 {As in IBC}
(Ord. 24-341 Section 1.)