Construction standards.
Cape Coral Land Development Code § 5.4.10
in effectSection 5.4.10. - Construction standards.
A. All wooden pilings used in connection with marine improvements subject to the terms of this section shall be made of pressure treated wood. Such pilings shall conform to the specifications contained in ASTM (American Society for Testing of Material) D25-88 and shall be treated with preservatives meeting standards of AWPA (American Wood Preservers Association) Standard P-5. The minimum retention of preservative for such wooden pilings shall be 2.5 pounds per cubic foot (p.c.f.) of chromated copper arsenate (CCA) in the zone 0 to 1.5 inches from the surface of the piling and 1.5 pounds per cubic foot (p.c.f.) in the zone 1.5 to 2 inches from the surface of the piling.
B. All pilings made of precast concrete and used in connection with marine improvements subject to the terms of this section shall have a minimum concrete strength of 3,000 pounds per square inch (psi) at 28 days and shall be at least eight inches square in cross section.
C. All non-prestressed concrete pilings shall have at least four #5 epoxy-coated steel reinforcing bars the entire length of the piling and have at least two inches of concrete cover.
D. All wooden pilings used for the support of a marine improvement or as framing for a marine improvement shall have a minimum classification of eight-inch butt diameter.
E. All wooden pilings used for support of boat lifts, or other structures supporting marine vessels, shall conform to the specifications of the manufacturer of the boat lift or other structure supported by such wooden piling(s). However, in no event shall any wooden pilings used for support of boat lifts or other structures supporting marine vessels be less than eight inches in butt diameter.
F. All wood that is located below mean high water or that is in contact with the water in any way shall be treated to two and one-half per cubic foot (p.c.f.) CCA. All wood that is located above mean high water shall be treated to four-tenths per cubic foot (p.c.f.) CCA, except that decking may be treated to a minimum of twenty-five-one-hundredths per cubic foot (p.c.f.) CCA.
G. The elevation of pilings shall not exceed ten feet above the seawall cap or, if no seawall exists, 13 feet above mean water level.
H. The elevation of the decking of a marine improvement shall not exceed two feet above the seawall cap, or if no seawall exists, five feet above mean water level. For marine improvements located in the Caloosahatchee River, and for marine improvements, located in canals, within 300 feet of the platted shoreline of the Caloosahatchee River, the elevation of the decking shall not exceed four feet above the seawall cap, or if no seawall exists, seven feet above mean water level.
I. All pilings and/or mooring posts shall be offset a minimum of 3 feet from any storm drain outfall pipe. Such measurement shall be made from the outside edge of the outfall pipe to the center of the piling or mooring post.
J. The minimum nominal dimensions of stringers and headers shall be two inches by eight inches. Stringers shall be supported by through bolts to pilings or by headers through-bolted to pilings with machine bolts or carriage bolts. Such machine bolts or carriage bolts shall have a diameter of not less than one-half inch. Machine bolts also shall have a suitable washer under both head and nut while carriage bolts shall have a suitable washer under the nut only. Headers shall be used below center stringers for support.
K. Cross-bracing shall be either through-bolted with machine bolts or carriage bolts with a minimum diameter of one-half inch or fastened with lag bolts with a minimum diameter of one-half inch and a minimum length of six inches used in conjunction with a suitable washer under the head only.
L. All fasteners shall be either stainless steel or hot dipped galvanized steel or of a substance which, in terms of corrosion-resistance, is at least equal to stainless steel or hot dipped galvanized steel. The Building Official shall determine whether a proposed fastener is equivalent to either stainless steel or hot dipped galvanized steel in terms of corrosion-resistance.
M. All manufactured, re-manufactured, modified boat lifting devices and associated material or structural supplements, shall be certified by a Florida registered professional engineer. The capacity of the boat lift shall be affixed to the lift by the manufacturer and shall be affixed in a position as close as practicable to the lift controls.
N. Except as otherwise provided herein, all pilings within six feet of the seawall face shall be driven a minimum of four feet into the submerged bottom of the waterway. Except as otherwise provided herein, pilings more than six feet from the seawall face shall be driven a minimum of six feet into the submerged bottom of the waterway. If pilings cannot be set to the depth provided herein, then the use and installation of cross bracing and/or tie backs shall be required to ensure the structural integrity of the structure. All pilings, whether wooden or concrete, shall be installed using equipment that is suitable to accomplish the task effectively. However, all freestanding mooring posts or other pilings shall be driven a minimum of eight feet into the submerged bottom of the waterway.
O. Pilings shall be spaced in relation to stringer lumber size. However, when a single stringer of nominal dimensions less than or equal to two inches by eight inches is used, the space between any two consecutive pilings shall not exceed ten feet and eight inches (or 128 inches) when measured from the center of one piling to the center of the next consecutive piling. Any stringer splices shall occur within three feet of pilings. Scabs shall be not less than six feet in length and shall overlap the splice by not less than three feet and, if possible, bolted to the piling. Scabs shall not be used past the next to last piling in a row of pilings. Scabs shall be fastened using not less than six 20 penny, hot dipped galvanized steel nails per side. Stringers used for decking shall be spaced not more than 30 inches apart when measured from the center of one stringer to the center of the next consecutive stringer.
P. The minimum nominal thickness of all wooden decking shall be two inches. Decking shall be either nailed into place by means of not less than 12d nails or screwed into place by means of not less than three-inch screws. The fastener pattern for all wooden decking shall be arranged so as not to cause a continuous split in excess of 18 inches in length. Spacing between wooden decking shall not exceed one-half inch on docks projecting into canals or one inch on docks projecting into the Caloosahatchee River at the time of installation.
Q. Crossbracing shall be provided on every two closest adjacent pilings where water depth is more than eight feet from mean high water. Such cross bracing shall be oriented between 30 degrees and 45 degrees to the vertical. The actual dimension of any crossbracing shall be not less than two inches by six inches.
R. All docks permitted under this section that project from a parcel with a seawall shall have a ladder extending from the dock into the waterway. No ladder extending from a dock into a waterway shall be made of wood.
1. If one or more metal ladders are used in conjunction with a marine improvement, such ladders shall be made of stainless steel, anodized aluminum, or an equally corrosion-resistant material to be approved by the Building Official.
2. If one or more plastic ladders are used in conjunction with a marine improvement, such ladders shall be constructed of a stabilized polymer plastic material resistant to degradation when exposed to the daily stress of sunlight, heat, and water.
3. If a non-extendable ladder is used in conjunction with a marine improvement, such ladder shall be located so as to reach at least three feet under the surface of the water at low tide or to the bottom of the waterway, whichever is less.
4. If an extendable ladder is used in conjunction with a marine improvement, such ladder shall be required to have the ability to extend to a point at least three feet under the surface of the water at low tide or so as to reach to the bottom of the waterway, whichever is less. Extendable ladders shall be of a type that is capable of being pulled down by a person in the water without the use of tools.
S. Amber reflectors or amber reflective material with at least four square inches of reflective surface shall be placed on all freestanding mooring posts or other freestanding pilings as well as on the outside end pilings of all docks which project into a waterway. For purposes of this section, marine improvements which are "U"-shaped, "V"-shaped, "J"-shaped, or which otherwise have more than one section of the marine improvement projecting into the waterway shall have such reflectors or reflective material located on the outside end pilings of each section of the marine improvement which projects into the waterway. Such reflectors shall be located so as to be visible to vessels approaching in the waterway from any direction.
T. This section shall control the regulation, construction, and maintenance of marine improvements within the City of Cape Coral. If any part of this section conflicts with any other codes adopted by the city, the most restrictive provision shall apply. Furthermore, all such marine improvements shall conform to all requirements of the National Fire Code, this section, and other applicable law.
(Ord. 51-19, § 4, 11-18-2019; Ord. 80-21, § 4, 11-3-2021)
Source: City of Cape Coral, Florida, Code of Ordinances, City Charter and Land Development Code (Municode Library, library.municode.com)URL: https://library.municode.com/fl/cape_coral/codes/code_of_ordinances?nodeId=ART5DEST_CH4MAIM_S5.4.10COSTFetched: 11/4/2026