17.12.1040 - Amendment of NFPA 1225 - 22, Standard for emergency services communications.

The following sections of NFPA 1225 - 22 edition, Standard for Emergency Services Communications, are amended to read as follows: 18.12.3.3: Deleted 18.12.3.4 Backbone cables and backbone cable components in buildings or high-rise buildings shall be protected from attack by fire in accordance with one of the following: (1) Use of cable with a listed fire-resistance rating in accordance with the following: (a) Where the primary structural frame of a building is required to have a fire-resistance rating of 2 hours or more or is classified as heavy timber construction, the minimum fire resistance rating shall be 2 hours. (b) Where the primary structural frame of a building is required to have a fire-resistance rating of less than 2 hours, the minimum fire resistance rating shall be 1 hour. (2) Deleted (3) A protected enclosure or area shall have a fire resistance rating in accordance with the following: (a) Where the primary structural frame of a building is required to have a fire-resistance rating of 2 hours or more or is classified as heavy timber construction, the minimum fire resistance rating shall be 2 hours. (b) Where the primary structural frame of a building is required to have a fire-resistance rating of less than 2 hours, the minimum fire resistance rating shall be 1 hour. (c) Deleted 18.12.3.7 RF-emitting device and active system components shall be located in a room that matches the required fire-resistance rating of the building's primary structural frame, with a maximum of 2 hours and a minimum of 1 hour. 18.14.12 The system shall comply with all of the following: (1) Monitoring for integrity of the system shall comply with chapter 10 of NFPA 72. (2) System supervisory signals shall include the following: (a) Signal Source malfunction (b) Active RF-emitting device failure (c) Low-battery capacity indication when numerical 70% of the 12-hour operating battery capacity has been depleted (d) Active and passive system component (distribution antenna loop) failure (3) Power supply supervisory signals shall include the following for each RF-emitting device and active systems components: (a) Loss of normal ac power (b) Failure of battery charger (4) The communications link between the fire alarm system and the in-building emergency responder communications enhancement system shall be monitored for integrity. (5) Where approved by the AHJ, a single supervisory input to the fire alarm system to monitor all system supervisory signals shall be permitted. 18.14.2.2 The annunciator shall provide visual and labeled indications of the following for each system component and RF-emitting device: (1) Normal ac power (2) Loss of normal ac power (3) Battery charger failure (4) Low-battery capacity (i.e., to 70 percent depletion (5) Signal source malfunction (6) Active RF-emitting device malfunction (7) Active and passive system component (distribution antenna loop) malfunction.

(Ord. 31258.)

Ask a question about San Jose law

Corpus searches the San Jose sections it holds and shows the ones that match, with their citations. Free, no sign-in.