34.604 - ELECTRICAL EQUIPMENT, WIRING AND HAZARDS.
The following requirements are in addition to the requirements found in IFC section 603: (Am. by ORD-18-00103, 10-23-18) (1) Extension Cords and Relocatable Power Taps. (a) Definitions. "Extension cord" means a cord set consisting of a length of flexible cord with an attachment plug at one end and a cord connector, which permits the connection of one or more attachment plugs, at the other end. "Relocatable power tap" means a system consisting of an attachment plug cap and a length of flexible cord terminated in an enclosure in which one or more receptacles are mounted. A relocatable power tap may be provided with supplementary overcurrent protection, switches, indicator lights, transient voltage surge suppressors, or electromagnetic interference filters. (b) Listing. Extension cords and relocatable power taps shall be listed by an approved nationally recognized testing agency. (c) General Requirements. 1. Extension cords shall only be used for temporary wiring and shall not be substituted for permanent wiring. 2. Extension cords shall be of a 3-wire grounding type when used in conjunction with devices equipped with 3-prong grounding type attachment plugs. (d) Ampacity. The current carrying capacity of the extension cord or relocatable power tap may not be exceeded. (e) Use of Extension Cords and Relocatable Power Taps. 1. Except as provided in subdivision (1)(c), extension cords and relocatable power taps may not be multiplied or plugged into one another. 2. Extension cords may be used for temporary wiring at construction sites provided the cords comply with Article 305 of the National Electrical Code as adopted in Wis. Admin. Code ch. SPS 316. (Am. by ORD-12-00035, 3-28-12) 3. Extension cords shall be permitted only with portable appliances, hand tools or fixtures. 4. Relocatable power taps are permitted only with portable electronic equipment such as audio-visual equipment, computers and peripheral equipment. 5. Except for listed adapter cord sets intended for construction site use, each extension cord shall serve only one portable appliance, hand tool or fixture. (f) Physical Protection. 1. Extension cords and relocatable power taps shall be protected from physical impact and environmental damage. 2. Extension cords and relocatable power taps may not be attached to structures or placed under doors or floor coverings.
(Renumb. by ORD-18-00103, 10-23-18; Am. by ORD-22-00122, 12-3-22)
Ask a question about Madison law
Corpus searches the Madison sections it holds and shows the ones that match, with their citations. Free, no sign-in.