§ 33.218.100 — Standards for Primary and Attached Accessory Structures in Single-Dwelling Zones

Portland City Code (non-zoning titles; Title 33 separately); partial · Portland Zoning Code § 33.218.100

Corpus is an independent public-information project, not the official City of Portland website. Stable reference: corpuslaw.us/code/040aeff0-8896-4d3a-9072-5c2a6bce42e7

33.218.100 Standards for Primary and Attached Accessory Structures in Single-Dwelling Zones

The standards of this section apply to development of new primary and attached accessory structures in single-dwelling zones. A. Landscaping. Landscaping must be provided between structures and the street, as follows: 1. Foundation landscaping. All street-facing elevations must have landscaping along their foundation. The landscaped area may be along the outer edge of a porch instead of the foundation. This landscaping requirement does not apply to portions of the building facade that provide access for pedestrians or vehicles to the building. The foundation landscaping must meet the following standards: a. The landscaped area must be at least 3 feet wide; b. There must be at least one three-gallon shrub for every 3 lineal feet of foundation; and c. Ground cover plants must fully cover the remainder of the landscaped area; and 2. Front yard trees. There must be at least one tree in front of each residential structure. On corner lots, there must be one tree for each 30 feet of frontage on the side street. B. Front setbacks in the Southwest Community Plan area and conservation districts. In the Southwest Community Plan area, shown on Map 825-4, and in conservation districts, the setback for primary buildings is based on the setbacks of primary buildings on the lots that abut each side of the site and are on the same street. The primary structure may be no closer to the front lot line than the adjacent primary structure that is closest to the front lot line. The primary structure may be no further from the front lot line than the adjacent primary structure that is farthest from the front lot line. In any case, the structure may not be set back from the front lot line more than 25 feet. C. Large building elevations divided into smaller areas. The front elevation of large structures must be divided into smaller areas or planes. When the front elevation of a structure is more than 500 square feet in area, the elevation must be divided into distinct planes of 500 square feet or less. For the purpose of this standard, areas of wall that are entirely separated from other wall areas by a projection, such as the porch or a roof over a porch, are also individual building wall planes. This division can by done by: 1. A porch, a dormer that is at least 4 feet wide, or a balcony that is at least 2 feet deep and is accessible from an interior room; 2. A bay window that extends at least 2 feet; or 3. Recessing a section of the facade by at least 2 feet; the recessed section must be at least 6 feet long. D. Roofs. 1. Primary structures must have a roof that is either: a. Sloped, with a pitch that is no flatter than 6/12 and no steeper than 12/12; or b. No steeper than and no flatter than the pitch of the roofs of the primary structures on the lots that abut either side of the site and front onto the same street. 2. Flat roofs are allowed when the space on top of the roof is no more than 150 square feet and accessible from an interior room, or as specified in subparagraph D.1.b, above. E. Main entrance. Cottage clusters are exempt from this standard. 1. Location of main entrance. The main entrance of each primary structure must face the street. On corner lots the main entrance may face either of the streets or be oriented to the corner. For single dwelling, duplex, and triplex buildings that have more than one main entrance only one entrance must meet this requirement. 2. Front porch at main entrance. There must be a front porch at all main entrances that face a street. If the porch projects out from the building, it must have a roof. If the roof of a required porch is developed as a deck or balcony, it may be flat. If the main entrance is to a single dwelling, the covered area provided by the porch must be at least 48 square feet and a minimum of 8 feet wide. If the main entrance is to more than one dwelling unit, the covered area provided by the porch must be at least 63 square feet and a minimum of 9 feet wide. 3. Covered balcony. For attached houses, a covered balcony on the same facade as the main entrance may be provided instead of a front porch. The covered portion of the balcony must be at least 48 square feet and a minimum of 8 feet wide. The floor of the covered balcony must be no more than 15 feet above grade, and must be accessible from the interior living space of the house. 4. Ornamental columns. If the front porch or covered balcony at a main entrance provides columns as corner supports, the columns must be ornamental columns that meet one of the following standards. Wrought iron style porch supports do not meet this standard: a. Large columns that are divided visually into clear areas of top, center, and bottom. Large rectilinear columns are at least 8" x 8", large rounded columns have a diameter of at least 8 inches; or b. Groupings of 2, 3, or 4 small columns that are divided visually into clear areas of top, center, and bottom. Small rectilinear columns are at least 4" x 4", small rounded columns have a diameter of at least 4 inches. 5. Openings between porch floor and ground. Openings of more than 1 foot between the porch floor and the ground must be covered with a solid material or lattice. Vehicle areas. F. 1. Alleys. If the site is served by an alley, access for motor vehicles must be from the alley, not from a street frontage. 2. Parking areas in the front setback. Parking areas may not be located in the front setback. 3. Vehicle areas between the porch and the street. Vehicle areas may not be located between the building’s porch or porches and an adjacent street. 4. Attached garages. When parking is provided in a garage attached to the primary structure, and garage doors face a street, the following standards must be met: a. The garage must not be more than 40 percent of the length of the street-facing facade or 12 feet long, whichever is greater; b. The front of the garage can be no closer to the front lot line than the front facade of the house; c. Garage doors may be no more than 75 square feet in area; and d. There may be no more than two individual garage doors. 5. Driveways. Driveways for attached houses must meet the following. See Figures 218-1 and 218-2 for examples of driveways that meet the standard. a. Driveways may be paired so that there is a single curb-cut providing access to two attached houses. The maximum width allowed for the paired driveway is 18 feet; and b. There must be at least 18 feet between single or paired driveways. Distance between driveways is measured along the front property line. G. Foundation material. Plain concrete block or plain concrete may be used as foundation material if the foundation material is not revealed more than 3 feet above the finished grade level adjacent to the foundation wall. H. Exterior finish materials. The standards of this subsection must be met on all building facades. 1. Plain concrete block, plain concrete, corrugated metal, plywood, composite materials manufactured from wood or other products, and sheet pressboard may not be used as exterior finish material. 2. Composite boards manufactured from wood or other products, such as hardboard or hardplank, may be used when the board product is less than 6 inches wide. 3. Where wood products are used for siding, the siding must be shingles, or horizontal siding, not shakes. 4. Where horizontal siding is used, it must be shiplap or clapboard siding composed of boards with a reveal of 6 inches or less, or vinyl or aluminum siding that is in a clapboard or shiplap pattern where the boards in the pattern are 6 inches or less in width. 5. Siding material may not cover required window and door trim. Figure 218-1 Paired Driveways for Attached Houses

![](https://figures.74-208-44-221.nip.io/portland/20261114/8d5d60d4eec6960946fdd08189a6dac7e6a0a9c50e4d570373359a39d5e30307.png)

![Figure 218-1 Paired Driveways for Attached Houses](https://figures.74-208-44-221.nip.io/portland/20261114/ceee486ce11964fbb0e55dba3cf826041d39e341eea9db6187695633082c8463.png)

I. Architectural features. Each primary structure must have one of the following features on the front street-facing elevation: 1. Roof dormer placed a minimum of 3 feet from all the side building walls; 2. A porch roof with a gable end facing the street. The roof eaves of the porch must be the same height as the roof eaves of the building. The pitch of the porch roof must be between 6/12 and 12/12; or 3. A gable end facing the front lot line with one of the following in the gable area above the eave line: a. A window; or b. A trimmed vent. The trim must match the trim on the windows and the vent must be at least 4 square feet in area. J. Windows. At least 15 percent of the area of a street-facing facade must be windows. All street-facing windows must meet the following. Windows in rooms with a finished floor height 4 feet or more below grade are exempt from this standard: 1. Each window must be square or vertical—at least as tall as it is wide; or 2. A horizontal window opening may be created when: a. Two or more vertical windows are grouped together to provide a horizontal opening, and they are either all the same size, or no more than two sizes are used. Where two sizes of windows are used in a group, the smaller window size must be on the outer edges of the grouping. The windows on the outer edges of the grouping must be vertical; the center window or windows may be vertical, square, or horizontal; or b. There is a band of individual lites across the top of the horizontal window. These small lites must be vertical and cover at least 20 percent of the total height of the window. Figure 218-2 Single Driveways for Attached Houses

![](https://figures.74-208-44-221.nip.io/portland/20261114/7af3f638e777bfdacac0ca7fdd7c9c464150adb1ec46231c116dd230a4b039ea.png)

![Figure 218-2 Single Driveways for Attached Houses](https://figures.74-208-44-221.nip.io/portland/20261114/326751d5668fa451c6d00087916bb12a63c7f8337b60ac31ef21e86a03cd409d.png)

K. Trim. Trim must mark all building roof lines, porches, windows, and doors on all elevations. The trim must be at least 3-1/2 inches wide. Buildings with an exterior material of stucco or masonry are exempt from this standard. L. Exterior stairs and fire escapes. Exterior stairs, other than those leading to a main entrance, must be at least 40 feet from all streets. Fire escapes must be at least 40 feet from all streets. M. Roof eaves. Roof eaves must project from the building wall at least 12 inches on all elevations. N. Rooftop solar energy systems. 1. Rooftop solar energy systems must meet the following requirements: a. On a flat roof. The solar energy system must be mounted flush or on racks, with the system or rack extending no more than 5 feet above the top of the highest point of the roof, not including the parapet. Solar energy systems must also be screened from the street by: (1) An existing parapet along the street-facing facade that is as tall as the tallest part of the solar energy system; or (2) Setting the solar energy system back from the street-facing roof edges. For each foot of height that the portion of the system projects above the parapet, or roofline when there is no parapet, the system must be set back 4 feet. b. On a pitched roof. The plane of the system must be parallel with the roof surface, with the system no more than 12 inches from the surface of the roof at any point, and set back 3 feet from the roof edge and ridgeline. 2. Photovoltaic roofing shingles or tiles may be directly applied to the roof surface. 3. Photovoltaic glazing may be integrated into windows or skylights. O. Water cisterns. Above-ground cisterns for rainwater or greywater collection meet the following: 1. Cisterns with a capacity of more than 80 gallons, or racks of cisterns with a total capacity of more than 80 gallons, may not be attached to the front facade of the primary structure; and 2. Cisterns must either: a. Match the color of the adjacent building wall, the color of the trim, or the color of the rain gutter; or b. Be screened by development, plantings, or fences so they are not visible from the street. P. Additional standards for historic resources. The following standards are additional requirements for conservation districts and conservation landmarks. 1. Skylights. Skylights may not be on street-facing elevations. On all other elevations, the glass, plastic, or other transparent material must be parallel to the slope of the roof. 2. Ornamental columns. Corners of the porch roof on street-facing elevations must be supported with ornamental columns that meet one of the following standards. Wrought iron style porch supports do not meet this standard: a. Large columns that are divided visually into clear areas of top, center, and bottom. Large rectilinear columns are at least 8" x 8", large rounded columns have a diameter of at least 8 inches; or b. Groupings of 2, 3, or 4 small columns that are divided visually into clear areas of top, center, and bottom. Small rectilinear columns are at least 4" x 4", small rounded columns have a diameter of at least 4 inches. 3. Albina Community Plan area. The standards of this paragraph apply in the Albina Community Plan area, shown on Map 825-1: a. Floor level delineation. Each primary residential structure must reflect, on its street-facing elevations, all floor levels in the building, including the attic. The different floor levels must be delineated through the use of porch roofs, changes in materials or texture of materials, location of pediment and roof lines, overhangs and setbacks. b. Ground floor. The ground floor of a primary structure that is entirely above grade must be at least 2 feet above grade. Developments must meet the standards of Chapter 11, Accessibility, of the Oregon Structural Specialty Code. 4. Vertical building proportions in Eliot. In the Eliot Conservation District, the front facade of each primary structure must have vertical proportions. New development must meet one of the following standards: a. It must be higher than it is wide; or b. Where the size of the building requires horizontal proportions, the street-facing elevations must be divided into visually distinct areas with vertical proportions. This is accomplished through setbacks, use of vertical elements such as columns or multi-story bay windows, changes in materials or other architectural devices. 5. Historic setback pattern in Piedmont. In the Piedmont Conservation District, the front facades of primary structures must be set back exactly 25 feet from the front property line. On corner lots, this standard can be met on either frontage. 6. Woodlawn street pattern. Buildings may not be in the vacated portions of the angled street pattern in the Woodlawn Conservation District. 7. Rooftop solar energy systems. a. Rooftop solar energy systems must not increase the footprint of the structure, must not increase the peak height of the roof, and the system must be parallel to the slope of the roof; b. Solar energy systems may not be installed on a conservation landmark. 8. Photovoltaic glazing, roofing shingles, or tiles may not be installed on a conservation landmark. 9. Cisterns. Cisterns for rainwater or greywater collection may not be located closer to the street than the primary street-facing building facade and they must be screened by development, plantings, or fences so they are not visible from the street.