§ 14.04.145 — Section 1905.6.2 of the 2025 Edition of the California Building Code is amended to read as follows

Pasadena Municipal Code, California (Supp. No. 79: codified through Ordinance No. 7469, enacted May 18, 2026) · Pasadena Municipal Code § 14.04.145

Corpus is an independent public-information project, not the official City of Pasadena website. Stable reference: corpuslaw.us/code/04527525-255b-45ee-a9a4-a2d8e5e67021

14.04.145 - Section 1905.6.2 of the 2025 Edition of the California Building Code is amended to read as follows.

1905.6.2 Seismic design categories C, D, E, and F. 1. Structural plain concrete basement, foundation or other walls below the base as defined in ASCE/SEI 7 are permitted in detached one-and-two-family dwellings three stories or less in height constructed with stud-bearing walls. In dwellings assigned to Seismic Design Category D or E, the height of the wall shall not exceed 8 feet (2438 mm), the thickness shall be not less than 71/2 inches (190 mm), and the wall shall retain not more than 4 feet (1219 mm) of unbalanced fill. Walls shall have reinforcement in accordance with Section 14.6.1 of ACI 318. 2. Isolated footings of plain concrete supporting pedestals or columns are permitted, provided that the projection of the footing beyond the face of the supported member does not exceed the footing thickness. Exception: In detached one-and-two-family dwellings three stories or less in height, the projection of the footing beyond the face of the supported member is permitted to exceed the footing thickness. 3. Plain concrete footings supporting wall are permitted, provided that the footings have not fewer than two continuous longitudinal reinforcing bars. Bars shall not be smaller than No. 4 and shall have a total area of not less than 0.002 times the gross cross-sectional area of the footing. For footings that exceed 8 inches (203 mm) in thickness, not fewer than one bar shall be provided at the top and bottom of the footing. Continuity of reinforcement shall be provided at corners and intersections. Exceptions: a. Where assigned to Seismic Design Category C, detached one-and-two-family dwellings three stories or less in height constructed with stud-bearing walls are permitted to have plain concrete footings without longitudinal reinforcement. b. For foundation systems consisting of a plain concrete footing and a plain concrete stemwall, not fewer than one bar shall be provided at the top of the stemwall and at the bottom of the footing., c. Footings cast monolithically with a slab-on-grade shall have not fewer than one No. 4 bar at the top and bottom of the footing or one No. 5 bar or two No. 4 bars in the middle third of the footing depth. Structures assigned to Seismic Design Category C, D, E, or F shall not have elements of structural plain concrete except where concrete used for fill with a minimum cement content of two (2) sacks of Portland cement or cementitious material per cubic yard.

(Ord. No. 7461, § 5, 11-10-2025)

Ask a question about Pasadena law

Corpus searches the Pasadena sections it holds and shows the ones that match, with their citations. Free, no sign-in.