§ 18.47.050 — Backflow Prevention Methods and Devices

El Paso City Code (Supp. No. 95, Update 4: codified through Ordinance No. 019889, enacted June 23, 2026) · El Paso City Code § 18.47.050

Corpus is an independent public-information project, not the official City of El Paso website. Stable reference: corpuslaw.us/code/0521d4da-69e9-48d1-af37-f3c408244262

18.47.050 - Backflow Prevention Methods and Devices.

(a) Any irrigation system that is connected to the potable water supply must be connected through a backflow prevention method approved by the Texas Commission on Environmental Quality (TCEQ). The backflow prevention device must be approved by the American Society of Sanitary Engineers; or the Foundation for Cross-Connection Control and Hydraulic Research, University of Southern California; or the International Plumbing Code; or any other laboratory that has equivalent capabilities for both the laboratory and field evaluation of backflow prevention assemblies. The backflow prevention device must be installed in accordance with the laboratory approval standards or if the approval does not include specific installation information, the manufacturer's current published recommendations. (b) If conditions that present a health hazard exist, one of the following methods must be used to prevent backflow; (1) Reduced pressure principle backflow prevention assemblies may be used if: (A) the device is installed at a minimum of 12 inches above ground in a location that will ensure that the assembly will not be submerged; and (B) drainage is provided for any water that may be discharged through the assembly relief valve. (2) Pressure vacuum breakers may be used if: (A) no back-pressure condition will occur; and (B) the device is installed at a minimum of 12 inches above any downstream piping and the highest downstream opening. Pop-up sprinklers are measured from the retracted position from the top of the sprinkler. (c) Backflow prevention devices used in applications designated as health hazards must be tested upon installation and annually thereafter. (d) If an existing irrigation system without a backflow-prevention assembly requires major maintenance, alteration, repair, or service, the system must be connected to the potable water supply through an approved, properly installed backflow prevention method before any major maintenance, alteration, repair, or service is performed. (e) If an irrigation system is connected to a potable water supply through a pressure vacuum breaker or reduced pressure principle backflow assembly and includes an automatic master valve on the system, the automatic master valve must be installed on the discharge side of the backflow prevention assembly. (f) The irrigation shall ensure the backflow prevention device is tested by a licensed Backflow Prevention Assembly Tester prior to being placed in service and the test results provided to the local water purveyor and the irrigation system's owner or owner's representative within ten business days of testing of the backflow prevention device.

(Ord. 17041, § 1, 12-23-2008)

Ask a question about El Paso law

Corpus searches the El Paso sections it holds and shows the ones that match, with their citations. Free, no sign-in.