For AI agents: read the machine-readable documentation index at /llms.txt or the single-file full reference at /llms-full.txt.

§ 31-84 — IPC CHAPTER 6 WATER SUPPLY AND DISTRIBUTION - amendments

Scottsdale Revised Code (Supp. No. 80: codified through Ordinance No. 4681, adopted July 1, 2025) · Scottsdale Revised Code § 31-84

Corpus is an independent public-information project, not the official City of Scottsdale website. Stable reference: corpuslaw.us/code/05a2d2f4-a321-40c9-97c4-824946abef07

Sec. 31-84. - IPC CHAPTER 6 WATER SUPPLY AND DISTRIBUTION - amendments.

Only the following portions of CHAPTER 6, WATER SUPPLY AND DISTRIBUTION, are amended: (a) Section 603.1, Size of water service pipe, is amended to read as follows: 603.1 Size of water service pipe. The water service pipe shall be sized to supply water to the structure in the quantities and at the pressures required in this code. The water service pipe shall be not less than 1 inch (25 mm) inside diameter. Replaced water service pipes shall be at least the same size as the pipe being replaced. In single-family dwellings where the total square footage under roof exceeds 12,000 square feet, the meter size shall be at least 1 1/2 inches (38 mm), and the supply pipe from the meter to the building shall be at least 2 inch (50mm) inside diameter. (b) Table 604.4, Maximum Flow Rates and Consumption for Plumbing Fixtures and Fixture Fittings, is amended to read as follows: TABLE 604.4 MAXIMUM FLOW RATES AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FITTING FIXTURE | MAXIMUM FLOW RATE OR QUANTITY b Lavatory, private | 1.5 gpm at 60 psi Lavatory, public (metering) | 0.25 gallon per metering cycle Lavatory, public (other than metering) | 0.5 gpm at 60 psi Shower head a | 2.0 gpm at 80 psi Residential kitchen faucet c | 1.8 gpm at 60 psi Sink faucet | 2.2 gpm at 60 psi Urinal | 0.5 gallon per flushing cycle Water closet | 1.28 gallons per flushing cycle d,e For SI: 1 gallon = 3.785 L, 1 gallon per minute = 3.785 L/m. 1 pound per square inch = 6.895 kPa. a. The total flow rate from all shower outlets controlled by one valve shall not exceed 2.0 gpm. This includes hand-held sprays, body sprays, jets, waterfalls, and rain systems. b. Consumption tolerances shall be determined from referenced standards. c. Kitchen faucets shall be permitted to temporarily increase the flow greater than 1.8 gpm but shall not exceed 2.2 gpm and must automatically revert to the established maximum flow rate of 1.8 gpm upon physical release of the activation mechanism or closure of the faucet valve. d. For dual flush, the full-flush volume shall not exceed 1.28 gallons. e. A 1.6 gallon per flushing cycle is permitted where a water closet is connected to a building's existing sanitary drainage piping.

(Ord. No. 4550, § 1(Res. No. 12501, § 1(Exh. A)), 9-20-22, eff. 1-1-23)

Ask a question about Scottsdale law

Corpus searches the Scottsdale sections it holds and shows the ones that match, with their citations. Free, no sign-in.