6.4.7. - Commercial Buildings.
(1) Purpose: These standards are designed to:
(a) Promote a quality, urban streetscape;
(b) Promote a pedestrian-friendly environment;
(c) Establish a variety of mixed uses in the core of the community;
(d) Provide an orderly development pattern;
(e) Maintain a supply of developable land while preserving the compact development;
(f) Improve traffic circulation and promote alternatives to automobile travel;
(g) Provide housing opportunities within walking distances of employment, service, and retail opportunities;
(h) Maintain an overall design theme;
(i) Preserve a human scale for new buildings;
(j) Provide economic development opportunities through clean industry, office, and commercial uses; and
(k) Provide for the daily needs and services of the community.
(l) These standards are not intended to restrict imagination, innovation, or variety.
(2) Applicability: Unless otherwise specified in this chapter, this section applies to any commercial building or structure of 5,000 square feet or more gross floor area. Subsections 7, 8, and 9 shall not apply to commercial buildings or structures of 5,000 square feet or more gross floor area, located on property developed or to be developed to conventional standards as provided in Chapter 4 and Section 6.3.2. of this Code. Subsections 6, 10, and 11 only shall apply to commercial buildings or structures of 2,000 square feet to 4,999 square feet.
(3) Flexibility: The standards in this section are intended to be applied with flexibility, allowing substitution of materials or construction methods, as long as the modification does not materially detract from the "Flexibility Options" section in Chapter Four provisions for the zoning district.
(4) Pedestrian Facilities: Continuous internal pedestrian walkways shall be provided to connect off-street parking areas with primary building entrances. At least one internal pedestrian walkway with a minimum width of five feet shall be provided from the on-site pedestrian network to the public sidewalk. In the case of corner lots, a connection shall be made to the sidewalk of both streets. All internal pedestrian walkways shall be distinguished from driving surfaces through the use of surface materials such as pavers, bricks or scored or stamped concrete or asphalt to enhance pedestrian safety and comfort, as well as the attractiveness of the walkways.
(5) Building Structure: Base, middle, and cap: Buildings exceeding two stories shall incorporate a base, a middle, and a cap described as follows:
(a) The base shall include an entryway with transparent windows as set forth in the ground-floor design standards of this chapter, and a molding or reveal placed between the first and second stories or over the second story.
(b) The molding or reveal shall have a depth of at least two inches and a height of at least four inches;
(c) The middle may include windows and/or balconies; and
(d) The cap shall include the area from the top floor to the roof of the building, and shall include a cornice or a roof overhang.
(6) Exterior Materials: The materials used on building facades shall include a percentage of masonry equal to the highest percentage of masonry on any building in the immediate context area consisting of the same property, adjacent properties, and other properties facing the same street segment, except that:
(a) Where none of the lots in the immediate context area are developed, the following exterior materials may be used: brick, stone, cementuous stucco, integrally colored unit masonry, split face block or similar designer block, with up to 25 percent of a facade consisting of exterior insulating finish system materials; and
(b) In redevelopment areas or industrial zoning districts where no existing buildings have more than 50 percent masonry on building facades facing a street, new buildings shall provide a minimum of 50 percent masonry on the building facade(s) facing a street.
(7) Ground-Floor Design:
(a) All buildings subject to this section shall have their principal entrance opening to a street, square, plaza, or sidewalk. The principal entrance shall not open onto a parking lot.
(b) Pedestrian access from the public sidewalk, street right-of-way, or driveway to the principal structure shall be provided through an improved surface.
(c) The ground floor of the entryway shall align with the sidewalk elevation. Sunken terraces or stairways to a basement shall not constitute entryways for purposes of this section.
(d) It is not the intent of this section to preclude the use of below-grade entryways, provided, however, that such entryways shall not constitute a principal entryway and shall not be used to satisfy the distancing requirements of the Windows and Entryways section of this chapter.
(8) Street Wall: Where a maximum front setback has been established, the front building wall or courtyard shall adjoin the sidewalk. The side setback shall be a minimum of zero feet and a maximum of ten feet.
(9) Windows and Entryways:
(a) Windows above the ground floor shall have a minimum ratio of height to width of 2:1.
(b) The ground floors of all buildings shall be designed to encourage and to complement pedestrian scale activity by the use of windows and doors arranged so that the uses are visible from and/or accessible to the street on at least 50 percent of the length of the first floor street frontage.
(c) Where windows are used, they shall be transparent.
(d) Solid walls shall not exceed 20 feet in length.
(e) All street-level retail uses with sidewalk frontage shall be furnished with an individual entrance and direct access to the sidewalk in addition to any other access that may be provided. This standard shall not apply to any lot with a street frontage of less than 24 feet.
(f) Doors shall be recessed into the face of the building to provide a sense of entry and to add variety to the streetscape. An entryway shall not be less than five percent of the wall area of the facade or ten percent of the length of the facade. In all cases the entry way shall not be less than 20 percent square feet.
(g) The maximum setback requirements may be waived by the Director of Development Services for an area not to exceed 90 percent percent of the frontage in order to accommodate courtyards.
(h) Canopies, awnings, and similar appurtenances may be constructed at the entrance to any building, subject to the criteria established in the International Building Codes.
(10) Mechanical Equipment. Mechanical equipment, electrical meter and service components, and similar utility devices, whether ground level, wall mounted, or roof mounted, shall be screened from view at the front property line. Solid waste containers shall be screened from view from all directions.
(11) Screening:
(a) Exterior screening materials shall be the same as the predominant exterior materials of the principal building, except that solid waste containers shall be enclosed with a solid masonry wall and opaque gate.
(b) In cases where the front property line is higher than the roof line of the subject building, no screening shall be required for a line of sight exceeding five feet six inches above the finished elevation of the property at the front property line.
(12) Fire Protection Equipment. A single centralized location for fire protection equipment controls shall be provided in each multi-tenant building.